![Fuji Electric FRENIC-Ace series Скачать руководство пользователя страница 321](http://html1.mh-extra.com/html/fuji-electric/frenic-ace-series/frenic-ace-series_user-manual_2341846321.webp)
5.3 Description of Function Codes
5-151
FU
NCT
IO
N
C
O
DE
S
Chap 5
P06 to P08 Motor 1 (No-load current, %R1 and %X)
P06 through P08 specify no-load current, %R1 and %X, respectively. Obtain the appropriate values from the test
report of the motor or by calling the manufacturer of the motor. Performing auto-tuning automatically sets these
parameters.
•
No-load current: Input the value obtained from the motor manufacturer.
•
%R1: Enter the value calculated by the following expression.
(%)
100
×
)
I
×
3
(
/
V
R1
Cable
R1
%R1
+
=
R1: Primary resistance of the motor (Ω)
Cable R1: Resistance of the output cable (Ω)
V: Rated voltage of the motor (V)
I: Rated current of the motor (A)
•
%X: Enter the value calculated by the following expression.
(%)
100
×
)
I
×
3
(
/
V
X
Cable
XM)
(X2
/
XM
×
X2
X1
%X
+
+
+
=
X1: Primary leakage reactance of the motor (Ω)
X2: Secondary leakage reactance of the motor (converted to primary) (Ω)
XM: Exciting reactance of the motor (Ω)
Cable X: Reactance of the out
put cable (Ω)
V: Rated voltage of the motor (V)
I: Rated current of the motor (A)
For reactance, use the value at the base frequency (F04).
P09 to P11 Motor 1 (slip compensation gain for driving, slip compensation response time and slip
compensation gain for braking)
P09 and P11 determine the slip compensation amount in % for driving and braking individually and adjust the slip
amount from internal calculation. Mode of 100% fully compensates for the rated slip of the motor. Excessive
compensation (100% or more) may cause hunting (undesirable oscillation of the system), so carefully check the
operation on the actual machine.
P10 determines the response time for slip compensation. Basically, there is no need to modify the default setting. If
you need to modify it, consult your Fuji Electric representatives.
Function code
Operation (slip compensation)
P09
Slip compensation gain for
driving
Adjust the slip compensation amount for driving.
Slip compensation amount for driving =
Rated slip × Slip compensation gain for driving
P11
Slip compensation gain for
braking
Adjust the slip compensation amount for braking.
Slip compensation amount for braking =
Rated slip × Slip compensation gain for braking
P10
Slip compensation
response time
Specify the slip compensation response time. Basically, there is no
need to modify the setting.
For details about slip compensation control, refer to the description of F42.
Содержание FRENIC-Ace series
Страница 20: ......
Страница 32: ......
Страница 92: ......
Страница 94: ......
Страница 452: ......
Страница 490: ......
Страница 504: ......
Страница 506: ...8 2 Frequency Setting Section 8 2 8 2 Frequency Setting Section Figure 8 2 1 Frequency Setting Section Block Diagram...
Страница 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Страница 514: ...8 6 Control Section 8 10 3 With speed sensor Figure 8 6 3 V f Control with speed sensor Section Block Diagram...
Страница 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Страница 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Страница 582: ......
Страница 646: ...11 9 Power Regenerative PWM Converters RHC Series 11 42 11 9 5 External dimensions PWM converter Boosting reactor...
Страница 649: ...11 9 Power Regenerative PWM Converters RHC Series 11 45 SELECTING PERIPHERAL EQUIPMENT Chap 11 Charging resistor Fuse...
Страница 664: ...11 15 External Cooling Fan Attachments 11 60...
Страница 690: ......
Страница 692: ......
Страница 720: ......
Страница 738: ......
Страница 787: ......