![Fuji Electric FRENIC-Ace series Скачать руководство пользователя страница 182](http://html1.mh-extra.com/html/fuji-electric/frenic-ace-series/frenic-ace-series_user-manual_2341846182.webp)
5.2 Function Codes Table
5-12
Code
Name
Data setting range
C
han
ge
w
hen
ru
nni
ng
D
ata
c
opy
in
g
Factory
Default
Drive control
R
el
at
ed
p
ag
e
V
/f
PG
V/
f
w
/ P
G
To
rq
ue c
on
tro
l
PM
33 (1033): Reset PID integral and differential terms
“PID-RST”
Y Y Y N Y
34 (1034): Hold PID integral term
“PID-HLD”
Y Y Y N Y
35 (1035): Select local (Keypad) command
“LOC”
Y Y Y Y Y
42 (1042): Activate the limit switch at start point *5
“LS”
Y Y N N N
43 (1043): Start / Reset *5
“S/R”
Y Y N N N
44 (1044): Switch to the serial pulse receiving mode *5
“SPRM”
Y Y N N N
45 (1045): Enter the return mode *5
“RTN”
Y Y N N N
46 (1046): Enable overload stop
“OLS”
Y Y Y N Y
47 (1047): Servo lock command *5
“LOCK”
N N Y N N
49 (1049): Pulse train sign
“SIGN”
Y Y Y N Y
59 (1059): Enable battery-driven operation *11
“BATRY/UPS”
Y Y Y N N
60 (1060): Select torque bias1 *5
“TB1”
N N Y N N
61 (1061): Select torque bias2 *5
“TB2”
N N Y N N
62 (1062): Hold torque bias *5
“H-TB”
N N Y N N
65 (1065): Check brake
“BRKE”
Y Y Y N N
70 (1070): Cancel line speed control *5
“Hz/LSC”
Y Y Y N N
71 (1071): Hold line speed control frequency in the memory
*5
“LSC-HLD”
Y Y Y N N
72 (1072): Count the run time of commercial power-driven
motor 1 *5
“CRUN-M1”
Y Y Y Y N
73 (1073): Count the run time of commercial power-driven
motor 2 *5
“CRUN-M2”
Y Y Y Y N
76 (1076): Select droop control
“DROOP”
Y Y Y N N
78 (1078): Select speed control parameter 1 *5 “MPRM1”
N Y Y Y Y
79 (1079): Select speed control parameter 2 *5 “MPRM2”
N Y Y Y Y
80 (1080): Cancel customizable logic
“CLC”
Y Y Y Y Y
81 (1081): Clear all customizable logic timers
“CLTC”
Y Y Y Y Y
82 (1082): Cancel anti-regenerative control
“AR-CCL”
Y Y Y N Y
98:
Run forward / stop command
“FWD”
Y Y Y Y Y
99:
Run reverse / stop command
“REV”
Y Y Y Y Y
100:
No function assigned
“NONE”
Y Y Y Y Y
171 (1171): PID control multistage command 1 “PID-SS1”
Y Y Y N Y
172 (1172): PID control multistage command 2 “PID-SS2”
Y Y Y N Y
* Inside the ( ) is the negative logic signal. (OFF at
short-circuit)
*5: Available at ROM version 0300 or later.
*11: Available at ROM version 0500 or later.
Содержание FRENIC-Ace series
Страница 20: ......
Страница 32: ......
Страница 92: ......
Страница 94: ......
Страница 452: ......
Страница 490: ......
Страница 504: ......
Страница 506: ...8 2 Frequency Setting Section 8 2 8 2 Frequency Setting Section Figure 8 2 1 Frequency Setting Section Block Diagram...
Страница 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Страница 514: ...8 6 Control Section 8 10 3 With speed sensor Figure 8 6 3 V f Control with speed sensor Section Block Diagram...
Страница 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Страница 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Страница 582: ......
Страница 646: ...11 9 Power Regenerative PWM Converters RHC Series 11 42 11 9 5 External dimensions PWM converter Boosting reactor...
Страница 649: ...11 9 Power Regenerative PWM Converters RHC Series 11 45 SELECTING PERIPHERAL EQUIPMENT Chap 11 Charging resistor Fuse...
Страница 664: ...11 15 External Cooling Fan Attachments 11 60...
Страница 690: ......
Страница 692: ......
Страница 720: ......
Страница 738: ......
Страница 787: ......