5.3 Description of Function Codes
5-133
FU
NCT
IO
N
C
O
DE
S
Chap 5
Related data is the following. These data are displayed and submitted with polarity. Judge the meaning of the
polarity by E49 setting.
Torque data
Data
Related data
Keypad LED monitor
E43=8
Calculated torque
E43=23
Torque current
Keypad drive monitor
3_04
Calculated torque
Keypad alarm information
6_03
Calculated torque when alarm
OPC-AIO
o90 = 4
Output torque (only o93=0:Bipolar)
Torque monitor function code
M02
Torque direction
M03
Torque current direction
M07
Output torque
M08
Torque current
M28
Torque direction when alarm
M29
Torque current direction when alarm
M33
Output torque when alarm
M34
Torque current when alarm
W07
Calculated torque
W24
Torque current
X23
Calculated torque when alarm
X63
Calculated torque when alarm
Z03
Calculated torque when alarm
Z53
Calculated torque when alarm
Z81
Output torque
E50
Display coefficient for speed monitor
E50 specifies the coefficient that is used when the load shaft speed or line speed is displayed on the LED monitor.
(Refer to the description of E43.)
Load shaft speed [min
-1
] = (E50: Display coefficient for speed monitor) × (Output frequency Hz)
Line speed [m/min] = (E50: Display coefficient for speed monitor) × (Output frequency Hz)
•
Data setting range: 0.01 to 200.00
E51
Display coefficient for “Input watt-hour data”
E51 specifies a display coefficient (multiplication factor) for displaying the input watt-hour data (
5_10
) in a part of
maintenance information on the keypad.
Input watt-hour data = Display coefficient (E51 data) × Input watt-hour (100kWh)
•
Data setting range: 0.000 (cancel/reset) 0.001 to 9999
Setting E51 data to 0.000 clears the input watt-hour and its data to “0.” After clearing, be sure to restore
E51 data to the previous value; otherwise, input watt-hour data will not be accumulated.
Содержание FRENIC-Ace series
Страница 20: ......
Страница 32: ......
Страница 92: ......
Страница 94: ......
Страница 452: ......
Страница 490: ......
Страница 504: ......
Страница 506: ...8 2 Frequency Setting Section 8 2 8 2 Frequency Setting Section Figure 8 2 1 Frequency Setting Section Block Diagram...
Страница 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Страница 514: ...8 6 Control Section 8 10 3 With speed sensor Figure 8 6 3 V f Control with speed sensor Section Block Diagram...
Страница 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Страница 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Страница 582: ......
Страница 646: ...11 9 Power Regenerative PWM Converters RHC Series 11 42 11 9 5 External dimensions PWM converter Boosting reactor...
Страница 649: ...11 9 Power Regenerative PWM Converters RHC Series 11 45 SELECTING PERIPHERAL EQUIPMENT Chap 11 Charging resistor Fuse...
Страница 664: ...11 15 External Cooling Fan Attachments 11 60...
Страница 690: ......
Страница 692: ......
Страница 720: ......
Страница 738: ......
Страница 787: ......