5.3 Description of Function Codes
5-167
FU
NCT
IO
N
C
O
DE
S
Chap 5
H30
Communication link function (Mode selection)
Related function codes: y98 bus link function (mode selection)
Using the RS-485 communications link, built-in CAN communications link or fieldbus (option) allows you to issue
frequency commands and run commands from a computer or PLC at a remote location, as well as monitor the
inverter running information and the function code data. It is possible to sets the source that specifies the
frequency and run commands with H30 and y98. H30 and y98 set the sources that specify RS-485
communications and fieldbus respectively.
When the built-in CAN communications link is enabled with y33 = 1, the fieldbus in the figure below is replaced with
the built-in CAN communications link.
Table 5.3-11 Command sources selectable
Command sources
Data
Inverter itself
Sources except RS-485 communications link and fieldbus
Frequency setting source: Specified by F01/C30, or multistep frequency
command
Operation method source: Via the keypad or digital input terminals selected by
F02
Via RS-485 communications
link (port 1)
Via the standard RJ-45 port used for connecting a keypad
Via RS-485 communications
link (port 2)
GB model and C model (for China):Via the terminals DX+, DX- and SD
GA model Via RJ-45 connector
Via fieldbus(option) or built-in
CAN
Via fieldbus (DeviceNet, PROFIBUS DP, etc.)
Via built-in CAN communications link
* C model (for China) and GB model is not equipped with the CAN communications link.
Table 5.3-12 Command sources specified by H30 (Communications link function, Mode selection)
H30 data
Frequency command
Run command source
0
Inverter itself (F01/C30)
Inverter itself (F02)
1
RS-485 communications link (port 1)
Inverter itself (F02)
2
Inverter itself (F01/C30)
RS-485 communications link (port 1)
3
RS-485 communications link (port 1)
RS-485 communications link (port 1)
4
RS-485 communications link (port 2)
Inverter itself (F02)
5
RS-485 communications link (port 2)
RS-485 communications link (port 1)
6
Inverter itself (F01/C30)
RS-485 communications link (port 2)
7
RS-485 communications link (port 1)
RS-485 communications link (port 2)
8
RS-485 communications link (port 2)
RS-485 communications link (port 2)
Inverter
RS-485 communications link
(port 1: RJ-45)
RS-485 communications link
(port 2: RJ-45 or terminal)
Fieldbus (option),
Built-in CAN
Selected setting
(frequency command
/run command)
Setting specified by H30 or
y98 applies when “LE” is
not assigned.
“LE”
Содержание FRENIC-Ace series
Страница 20: ......
Страница 32: ......
Страница 92: ......
Страница 94: ......
Страница 452: ......
Страница 490: ......
Страница 504: ......
Страница 506: ...8 2 Frequency Setting Section 8 2 8 2 Frequency Setting Section Figure 8 2 1 Frequency Setting Section Block Diagram...
Страница 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Страница 514: ...8 6 Control Section 8 10 3 With speed sensor Figure 8 6 3 V f Control with speed sensor Section Block Diagram...
Страница 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Страница 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Страница 582: ......
Страница 646: ...11 9 Power Regenerative PWM Converters RHC Series 11 42 11 9 5 External dimensions PWM converter Boosting reactor...
Страница 649: ...11 9 Power Regenerative PWM Converters RHC Series 11 45 SELECTING PERIPHERAL EQUIPMENT Chap 11 Charging resistor Fuse...
Страница 664: ...11 15 External Cooling Fan Attachments 11 60...
Страница 690: ......
Страница 692: ......
Страница 720: ......
Страница 738: ......
Страница 787: ......