![Fuji Electric FRENIC-Ace series Скачать руководство пользователя страница 410](http://html1.mh-extra.com/html/fuji-electric/frenic-ace-series/frenic-ace-series_user-manual_2341846410.webp)
5.3 Description of Function Codes
5-240
■
Start after synchronization mode
In Start after synchronization mode (d41 = 3), the inverter controls the follower motor to synchronize its Z phase
with the master motor’s Z phase, based on the first detected Z phases (positions) of those two motors after the
start of master-follower operation. The follower motor could cause a single cycle delay at a maximum (on standby)
at the start of operation.
Once the follower motor starts running after standby, it will never go standby unless the master-follower operation
is cancelled (see Note 1 below).
The Z phase synchronization angles of the master and follower motors can be adjusted with d76.
The inverter integrates the position pulses for each of the master and follower motors and controls the follower
motor’s rotation speed and position to keep the deviation between those two motors at zero.
If any incorrect count due to electrical noise or other factors is found in the integrated count of A/B phases, the
inverter corrects the error based on the Z phase difference.
If the deviation between those two motors falls below the synchronization completion detection angle (specified by
d77), the inverter issues an
“SY”
synchronization completion signal. If synchronization is lost so that the position
error exceeds 10 times of the excessive error setting (specified by d78), the inverter shuts down its output with the
ero
alarm.
360°
0°
360°
0°
t
t
t
t
t
t
OFF
ON
Reference PG
rotation speed
Run command
for slave motor
Slave PG
rotation speed
Reference PG
phase angle
Slave PG
phase angle
SY
output
Synchronization completed
Start of standby
Figure 5.3-24
Note 1:
Master-follower operation cancellation conditions
In any of the following cases, the master-follower operation is canceled.
•
The run command for the follower motor is turned OFF.
•
Terminal command
“BX”
(“Coast to a stop”) or
“STOP”
(“Force to stop”) is turned ON.
•
Any alarm occurs.
•
The inverter switches to a single motor drive. (Assign terminal command “
Hz2/Hz1
” and switch the frequency
setting source with F01/C30.)
•
Under torque control or when the inverter is driven by commercial power.
Follower PG
Rotation speed
Master PG
Phase angle
Follower PG
Phase angle
Master PG
Rotation speed
Run command for
follower motor
Follower PG
Rotation speed
Содержание FRENIC-Ace series
Страница 20: ......
Страница 32: ......
Страница 92: ......
Страница 94: ......
Страница 452: ......
Страница 490: ......
Страница 504: ......
Страница 506: ...8 2 Frequency Setting Section 8 2 8 2 Frequency Setting Section Figure 8 2 1 Frequency Setting Section Block Diagram...
Страница 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Страница 514: ...8 6 Control Section 8 10 3 With speed sensor Figure 8 6 3 V f Control with speed sensor Section Block Diagram...
Страница 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Страница 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Страница 582: ......
Страница 646: ...11 9 Power Regenerative PWM Converters RHC Series 11 42 11 9 5 External dimensions PWM converter Boosting reactor...
Страница 649: ...11 9 Power Regenerative PWM Converters RHC Series 11 45 SELECTING PERIPHERAL EQUIPMENT Chap 11 Charging resistor Fuse...
Страница 664: ...11 15 External Cooling Fan Attachments 11 60...
Страница 690: ......
Страница 692: ......
Страница 720: ......
Страница 738: ......
Страница 787: ......