10.3 Equations for Selections
10-14
10.3.4 Calculating the RMS rating of the motor
In case of the load which is repeatedly and very frequently driven by a motor, the motor current fluctuates largely
and enters the short-time rating range of the motor repeatedly. Therefore, you have to review the allowable thermal
rating of the motor. The heat value is assumed to be approximately proportional to the square of the motor current.
If an inverter drives a motor in duty cycles that are much shorter than the thermal time constant of the motor,
calculate the “equivalent RMS current” as mentioned below, and select the motor so that this RMS current will not
exceed the rated current of the motor.
Figure 10.3-7 Sample of the Repetitive Operation
First, calculate the required torque of each part based on the speed pattern. Then using the torque-current curve of
the motor, convert the torque to the motor current. The “equivalent RMS current, Ieq” can be finally calculated by
the following equation:
)
A
(
t
t
t
t
t
t
t
I
t
I
t
I
t
I
t
I
I
6
5
4
3
2
1
5
2
5
4
2
4
3
2
3
2
2
2
1
2
1
eq
+
+
+
+
+
⋅
+
⋅
+
⋅
+
⋅
+
⋅
=
(Equation 10.3-26)
The torque-current curve for the dedicated motor is not available for actual calculation. Therefore, calculate the
motor current I from the load torque
τ
1
using the following equation (Equation 10.3-27). Then, calculate the
equivalent current Ieq:
)
A
(
I
I
100
I
2
100
m
2
100
t
1
+
×
τ
=
(Equation 10.3-27)
Where,
τ
1
is the load torque (%), I
t100
is the torque current, and I
m100
is exciting current.
Содержание FRENIC-Ace series
Страница 20: ......
Страница 32: ......
Страница 92: ......
Страница 94: ......
Страница 452: ......
Страница 490: ......
Страница 504: ......
Страница 506: ...8 2 Frequency Setting Section 8 2 8 2 Frequency Setting Section Figure 8 2 1 Frequency Setting Section Block Diagram...
Страница 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Страница 514: ...8 6 Control Section 8 10 3 With speed sensor Figure 8 6 3 V f Control with speed sensor Section Block Diagram...
Страница 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Страница 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Страница 582: ......
Страница 646: ...11 9 Power Regenerative PWM Converters RHC Series 11 42 11 9 5 External dimensions PWM converter Boosting reactor...
Страница 649: ...11 9 Power Regenerative PWM Converters RHC Series 11 45 SELECTING PERIPHERAL EQUIPMENT Chap 11 Charging resistor Fuse...
Страница 664: ...11 15 External Cooling Fan Attachments 11 60...
Страница 690: ......
Страница 692: ......
Страница 720: ......
Страница 738: ......
Страница 787: ......