![Fuji Electric FRENIC-Ace series Скачать руководство пользователя страница 178](http://html1.mh-extra.com/html/fuji-electric/frenic-ace-series/frenic-ace-series_user-manual_2341846178.webp)
5.2 Function Codes Table
5-8
Code
Name
Data setting range
C
han
ge
w
hen
ru
nni
ng
D
at
a
co
py
in
g
Factory
Default
Drive control
R
el
at
ed
p
ag
e
V
/f
PG
V/
f
w
/ P
G
To
rq
ue c
on
tro
l
PM
71 (1071): Hold line speed control frequency in the memory
*5
“LSC-HLD”
Y Y Y N N
72 (1072): Count the run time of commercial power-driven
motor 1 *5
“CRUN-M1”
Y Y Y Y N
73 (1073): Count the run time of commercial power-driven
motor 2 *5
“CRUN-M2”
Y Y Y Y N
76 (1076): Select droop control
“DROOP”
Y Y Y N N
78 (1078): Select speed control parameter 1 *5 “MPRM1”
N Y Y Y Y
79 (1079): Select speed control parameter 2 *5 “MPRM2”
N Y Y Y Y
80 (1080): Cancel customizable logic
“CLC”
Y Y Y Y Y
81 (1081): Clear all customizable logic timers
“CLTC”
Y Y Y Y Y
82 (1082): Cancel anti-regenerative control
“AR-CCL”
Y Y Y N Y
100:
No function assigned
“NONE”
Y Y Y Y Y
171 (1171): PID control multistage command 1 “PID-SS1”
Y Y Y N Y
172 (1172): PID control multistage command 2 “PID-SS2”
Y Y Y N Y
* Inside the ( ) is the negative logic signal (OFF at
short-circuit)
E10 Acceleration time2
0.00 to 6000 s
* 0.00 is for acceleration and deceleration time cancel
(when performing soft-start and stop externally)
Y Y
6.00
or
20.0
*10
Y Y Y N Y 5-116
E11 Deceleration time2
Y Y
Y Y Y N Y
E12 Acceleration time 3
Y Y
Y Y Y N Y
E13 Deceleration time 3
Y Y
Y Y Y N Y
E14 Acceleration time 4
Y Y
Y Y Y N Y
E15 Deceleration time 4
Y Y
Y Y Y N Y
E16 Torque limiter 2
(Driving) 0 to 300%; 999 (Disable)
Y Y
999
Y Y Y Y Y 5-116
E17
(Braking) 0 to 300%; 999 (Disable)
Y Y
999
Y Y Y Y Y
E20 Terminal [Y1] function
0 (1000): Inverter running
“RUN” N Y
0
Y Y Y Y Y 5-117
E21 Terminal [Y2] function
1 (1001): Frequency (speed) arrival
“FAR” N Y
7
Y Y Y N Y
E27 Terminal [30A/B/C] function
(Relay output)
2 (1002): Frequency (speed) detected
“FDT” N Y
99
Y Y Y Y Y
3 (1003): Under voltage detected (inverter stopped) “LU”
Y Y Y Y Y
4 (1004): Detected torque polarity
“B/D”
Y Y Y Y Y
5 (1005): Inverter output limiting
“IOL”
Y Y Y Y Y
6 (1006): Auto-restarting after momentary power failure
“IPF”
Y Y Y Y Y
7 (1007): Motor overload early warning
“OL”
Y Y Y Y Y
8 (1008): Keypad operation enabled
“KP”
Y Y Y Y Y
10 (1010): Inverter ready to run
“RDY”
Y Y Y Y Y
15 (1015): Switch MC on the input power lines
“AX”
Y Y Y Y Y
16 (1016): Pattern operation stage transition
“TU”
Y Y Y N Y
17 (1017): Pattern operation cycle completed
“TO”
Y Y Y N Y
18 (1018): Pattern operation stage 1
“STG1”
Y Y Y N Y
19 (1019): Pattern operation stage 2
“STG2”
Y Y Y N Y
20 (1020): Pattern operation stage 4
“STG4”
Y Y Y N Y
21 (1021): Frequency (speed) arrival 2
“FAR2”
Y Y Y N Y
22 (1022): Inverter output limiting with delay
“IOL2”
Y Y Y Y Y
25 (1025): Cooling fan in operation
“FAN”
Y Y Y Y Y
26 (1026): Auto-resetting
“TRY”
Y Y Y Y Y
27 (1027): Universal DO
“U-DO”
Y Y Y Y Y
28 (1028): Heat sink overheat early warning
“OH”
Y Y Y Y Y
29 (1029): Synchronization completed *5
“SY”
N Y Y N N
30 (1030): Lifetime alarm
“LIFE”
Y Y Y Y Y
31 (1031): Frequency (speed) detected 2
“FDT2”
Y Y Y Y Y
33 (1033): Reference loss detected
“REF OFF”
Y Y Y N Y
35 (1035): Inverter outputting
“RUN 2”
Y Y Y Y Y
36 (1036): Overload prevention controlling
“OLP”
Y Y Y N Y
37 (1037): Current detected
“ID”
Y Y Y Y Y
38 (1038): Current detected 2
“ID2”
Y Y Y Y Y
39 (1039): Current detected 3
“ID3”
Y Y Y Y Y
*5: Available at ROM version 0300 or later.
*10: 6.00s for inverters of nominal applied motor 22kW or below; 20.0s for those of 30kW or above.
Содержание FRENIC-Ace series
Страница 20: ......
Страница 32: ......
Страница 92: ......
Страница 94: ......
Страница 452: ......
Страница 490: ......
Страница 504: ......
Страница 506: ...8 2 Frequency Setting Section 8 2 8 2 Frequency Setting Section Figure 8 2 1 Frequency Setting Section Block Diagram...
Страница 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Страница 514: ...8 6 Control Section 8 10 3 With speed sensor Figure 8 6 3 V f Control with speed sensor Section Block Diagram...
Страница 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Страница 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Страница 582: ......
Страница 646: ...11 9 Power Regenerative PWM Converters RHC Series 11 42 11 9 5 External dimensions PWM converter Boosting reactor...
Страница 649: ...11 9 Power Regenerative PWM Converters RHC Series 11 45 SELECTING PERIPHERAL EQUIPMENT Chap 11 Charging resistor Fuse...
Страница 664: ...11 15 External Cooling Fan Attachments 11 60...
Страница 690: ......
Страница 692: ......
Страница 720: ......
Страница 738: ......
Страница 787: ......