![Fuji Electric FRENIC-Ace series Скачать руководство пользователя страница 192](http://html1.mh-extra.com/html/fuji-electric/frenic-ace-series/frenic-ace-series_user-manual_2341846192.webp)
5.2 Function Codes Table
5-22
Code
Name
Data setting range
C
han
ge
w
hen
ru
nni
ng
D
at
a
co
py
in
g
Factory
Default
Drive control
R
el
at
ed
p
ag
e
V
/f
PG
V/
f
w
/ P
G
Tor
qu
e c
on
tro
l
PM
A23 Motor 2
(Slip compensation gain for
driving)
0.0 to 200.0%
Y* Y
100.0
Y Y Y N N
A24 (Slip compensation response
time)
0.01 to 10.00 s
Y Y1
Y2
0.50
Y Y N N N
A25
(Slip compensation gain for
braking)
0.0 to 200.0%
Y* Y
100.0
Y Y Y N N
A26
(Rated slip frequency) 0.00 to 15.00Hz
N Y1
Y2
*6
Y Y Y N N
A27
(Iron loss factor 1) 0.00 to 20.00%
Y Y1
Y2
*6
Y Y Y Y N
A30 (Magnetic saturation factor 1)
*5
0.0 to 300.0 %
Y Y1
Y2
*6
N N Y Y N
A31 (Magnetic saturation factor 2)
*5
0.0 to 300.0 %
Y Y1
Y2
*6
N N Y Y N
A32 (Magnetic saturation factor 3)
*5
0.0 to 300.0 %
Y Y1
Y2
*6
N N Y Y N
A33 (Magnetic saturation factor 4)
*5
0.0 to 300.0 %
Y Y1
Y2
*6
N N Y Y N
A34 (Magnetic saturation factor 5)
*5
0.0 to 300.0 %
Y Y1
Y2
*6
N N Y Y N
A39 Motor 2 selection
0: Motor characteristics 0 (Fuji standard IM, 8-series)
1: Motor characteristics 1 (HP rating IMs)
4: Other IMs
N Y1
Y2
U:1
ACEJK:0
Y Y Y Y N
A40 Slip compensation 2
(Operating conditions
selection)
0: Enable during acceleration/deceleration, enable at
base frequency or higher
1: Disable during acceleration/deceleration, enable at
base frequency or higher
2: Enable during acceleration/deceleration, disable at
base frequency or higher
3: Disable during acceleration/deceleration, disable at
base frequency or higher
N Y
0
Y Y N N N
A41 Output current fluctuation
damping gain for motor 2
0.00 to 1.00
Y
Y
0.20
Y Y N N N
A43 Speed control 2 *5
(Speed command filter)
0.000 to 5.000 s
Y
Y
0.020
N Y Y N Y 5-228
A44
(Speed detection filter) 0.000 to 0.100 s
Y* Y
0.005
N Y Y N Y
A45
P (Gain) 0.1 to 200.0 times
Y* Y
10.0
N Y Y N Y
A46
I (Integral time) 0.001 to 9.999 s; 999 (Cancel integral term)
Y
Y
0.100
N Y Y N Y
A47
FF (Gain) 0.00 to 99.99 s
Y
Y
0.00
N N Y N Y
A49
(Notch filter resonance
frequency)
1 to 200 Hz
Y
Y
200
N N Y N N
A50 (Notch filter attenuation level) 0 to 20 dB
Y
Y
0
N N Y N N
A51 Cumulative motor run time 2 0 to 9999
Change in cumulative motor run time (Reset is enabled)
(in units of 10 hours)
N N
–
Y Y Y Y N
–
A52 Startup counter for motor 2
For adjustment at replacement
(0000 to FFFF in hexadecimal)
Y N
–
Y Y Y Y N
A53 Motor 2
(%X correction factor 1)
0 to 300%
Y Y1
Y2
100
Y Y Y Y N
A55 (Torque current under vector
control) *5
0.00 to 2000 A
N Y1
Y2
*6
N N Y Y N
A56 (Induced voltage factor under
vector control) *5
50 to 100 %
N Y1
Y2
*6
N N Y Y N
A98 Motor 2
(Function selection)
0 to 255
(Data is displayed in decimal, Meaning of each bit 0:
Disable; 1 Enable)
bit0:
Current limiter (F43, F44)
bit1:
Rotational direction control (H08)
bit2:
Non-linear V/f (H50 to H53, H65, H66)
bit3:
PID control (J01 to J62, H91)
bit4:
Brake signal
bit5:
Braking timer at the Startup (H195)
Bit6 to 7: Reserved *9
N Y
0
Y Y Y Y Y 5-195
Factory default
A (For Asia), C (for China), E (for Europe), U (For USA), J (for Japan), K (for Korea)
*5: Available at ROM version 0300 or later.
*6: Factory defaults are depended on motor capacity. Refer to “5.2.4 Motor constant”.
*9: Factory use. Do not change these function codes.
Содержание FRENIC-Ace series
Страница 20: ......
Страница 32: ......
Страница 92: ......
Страница 94: ......
Страница 452: ......
Страница 490: ......
Страница 504: ......
Страница 506: ...8 2 Frequency Setting Section 8 2 8 2 Frequency Setting Section Figure 8 2 1 Frequency Setting Section Block Diagram...
Страница 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Страница 514: ...8 6 Control Section 8 10 3 With speed sensor Figure 8 6 3 V f Control with speed sensor Section Block Diagram...
Страница 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Страница 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Страница 582: ......
Страница 646: ...11 9 Power Regenerative PWM Converters RHC Series 11 42 11 9 5 External dimensions PWM converter Boosting reactor...
Страница 649: ...11 9 Power Regenerative PWM Converters RHC Series 11 45 SELECTING PERIPHERAL EQUIPMENT Chap 11 Charging resistor Fuse...
Страница 664: ...11 15 External Cooling Fan Attachments 11 60...
Страница 690: ......
Страница 692: ......
Страница 720: ......
Страница 738: ......
Страница 787: ......