15
SD3 Series Instruction Manual
Tuning
7
7. Tuning
2. Tuning Procedure
2. Tuning Procedure
x1
Y
N
Stage 2
Y
N
Parameter Saving Mode
② Inertia Ratio
x1 (press once)
・In the parameter saving mode, save the parameters
to EEPROM in the amplifier.
・If you shut down the amplifier without saving the parameters,
the setting changes will not take effect.
① Control Gain Set
Operation 1A
Change
Auto Tuning Mode
・No noise?
Set the value to 5
Enter the inertia ratio
Tuning complete
Change
Manually enter the inertia ratio.
(This is a sample image: the inertia ratio is 250 .)
Acceptable motion?
Final tuning
Visually check
the actual motion
.
Confirm
Confirm
Let the equipment system move.
Is the motor quiet?
・Shorter settling time
・Better responsiveness
・Less/no vibration
If you need to improve the response further, gradually increase
the control gain set within the range where the motor will not make noise
and perform tuning each time.
Saving complete
・Check the motor motion by test operation
or external command input.
・Repeat the system entire motion several times.
The following is desired:
Change the inertia ratio.
Operation 2
Quick Tuning on Setup Panel: Operation 1A
Содержание SD3 Series
Страница 1: ...R FATEK AUTOMATION CORP Instruction Manual AC SERVO MOTOR and SERVO AMPLIFIER SD3 Series...
Страница 6: ...6 MEMO SD3 Series Instruction Manual...
Страница 52: ...32 MEMO 2 Specifications SD3 Series Instruction Manual...
Страница 92: ...40 MEMO 3 Preparation SD3 Series Instruction Manual...
Страница 292: ...48 MEMO SD3 Series Instruction Manual 6 Operation...
Страница 338: ...46 MEMO SD3 Series Instruction Manual 7 Tuning...
Страница 362: ...24 MEMO 8 Troubleshooting SD3 Series Instruction Manual...
Страница 395: ...MEMO SD3 Series Instruction Manual...
Страница 396: ...R...