51
5
Setting Parameters
5. Setting Parameters
SD3 Series Instruction Manual
5. Parameters
5. Parameters
No. 87.0
Position deviation error detection:
Value
Range
Default
Characteristics
0 to 2,147,483,647
196,608
[encoder pulse]
Function
Use
This parameter sets a threshold value for a position deviation error detection.
The higher the value, the less likely to detect position deviation error.
(The initial value of 196,608 is equivalent to pulse count of rotor 1.5 rotations.)
Prerequisite
Position deviation error detection: Switch (No.65.0) = 1 (Enable)
Related To
No.65.0, No.89.0
No. 89.0
Position deviation error detection:
Delay time
Range
Default
Characteristics
0 to 32,767
(See below)
Function
Use
This parameter sets a delay time for a position deviation error (
Alarm
No.6) to be
output after the position deviation exceeded the setting of [Position deviation error
detection value (No.87.0)]
The higher the value, the longer it takes for the error to be output.
■ Default
Motor Capacity
Default
Converted to Time
50 W to 750 W
250 [160 µs]
40 ms
1 kW to 2 kW
200 [200 µs]
Prerequisite
Position deviation error detection: Switch (No.65.0) = 1 (Enable)
Related To
No.65.0, No.87.0
No. 90.0
Speed deviation error detection:
Value
Range
Default
Characteristics
0 to 32,767
(See below)
Function
Use
This parameter sets a threshold value for a speed deviation error detection.
The higher the value, the less likely to detect a speed deviation error.
■ Default
Motor Capacity
Default
Speed Conversion
50 W to 750 W
524 [encoder pulse/160 µs]
1,499 r/min
1 kW to 2 kW
655 [encoder pulse/200 µs]
Prerequisite
Speed deviation error detection - Switch (No.65.1) = 1 (Enable)
Related To
No.65.1, No.91.0
No. 91.0
Speed deviation error detection:
Delay time
Range
Default
Characteristics
0 to 32,767
(See below)
Function
Use
This parameter sets a delay time for a speed deviation error (
Alarm
No.5) to be
detected after the speed deviation exceeded the setting of "Speed deviation error -
Detection value"(No.90.0).
The higher the value, the longer the error detection time.
■ Default
Motor Capacity
Default
Converted to Time
50 W to 750 W
250 [160 µs]
40 ms
1 kW to 2 kW
200 [200 µs]
Prerequisite
Speed deviation error detection - Switch (No.65.1) = 1 (Enable)
Related To
No.65.1, No.90.0
-
-
-
-
Содержание SD3 Series
Страница 1: ...R FATEK AUTOMATION CORP Instruction Manual AC SERVO MOTOR and SERVO AMPLIFIER SD3 Series...
Страница 6: ...6 MEMO SD3 Series Instruction Manual...
Страница 52: ...32 MEMO 2 Specifications SD3 Series Instruction Manual...
Страница 92: ...40 MEMO 3 Preparation SD3 Series Instruction Manual...
Страница 292: ...48 MEMO SD3 Series Instruction Manual 6 Operation...
Страница 338: ...46 MEMO SD3 Series Instruction Manual 7 Tuning...
Страница 362: ...24 MEMO 8 Troubleshooting SD3 Series Instruction Manual...
Страница 395: ...MEMO SD3 Series Instruction Manual...
Страница 396: ...R...