70
5. Setting Parameters
SD3 Series Instruction Manual
5. Parameters
No. 226.0
Deceleration stop:
Operating time
Range
Default
Characteristics
0 to 16,383
(See below)
Function
Use
This parameter indicates deceleration stop operation time in case an alarm occurs
or the Servo ON signal turns OFF. It is used for a motor which is slowing down as
specified with the deceleration stop method (No.224.0).
■ Default
Motor Capacity
Default
Units
Converted to Time
50 W to 750 W
313
160 µs
50 ms
1 kW to 2 kW
250
200 µs
Prerequisite
Deceleration stop Method (upon servo off) (No.224.0) = 1 (Short brake) or 2 (Quick stop)
Related To
No.224.0, No.224.1, No.227.0
No. 227.0
Deceleration stop:
Cancellation speed
Range
Default
Characteristics
0 to 32,767
(See below)
Function
Use
This parameter indicates rotational speed to cancel deceleration-stop in case an
alarm occurs or the Servo ON signal turns OFF.
It is used for a motor which is slowing down as specified with the deceleration stop method (No.224.0).
■ Default
Motor Capacity
Default
Units [encoder pulse]
Conversion to Rotational Speed
50 W to 750 W
17
pulse/160 µs
50 r/min
1 kW to 2 kW
22
pulse/200 µs
Prerequisite
Deceleration stop: Method (No.224.0) = 1 (Short brake) or 2 (Quick stop)
& Deceleration stop: Release conditions (No.224.1) = 1
Related To
No.224.0, No.224.1, No.226.0
No. 228.0
Deceleration stop:
Operating time
(upon control power error)
Range
Default
Characteristics
0 to 16,383
(See below)
Function
Use
Set Deceleration stop time in the event of the alarm output due to a control power error.
■ Default
Motor Capacity
Default
Units
Converted to Time
50 W to 750 W
62
160 µs
10 ms
1 kW to 2kW
52
200 µs
Prerequisite
Deceleration stop: Switch (upon control power failure) (No.224.2) = 1 (Enable)
Related To
No.224.2
Common
Position Control Pulse Train Command
Position Control Internal Command
Velocity Control Analog Command
Velocity Control Internal Command
Torque Control Analog Command
Communication
Operation Mode
Operation Control
Alarm Detection
Tuning
Homing
Torque Limit
Deceleration Stop and so on
Vibration Control
Switch
Selection
Numeric Value
Control Power Cycle
2-Byte Data
4-Byte Data
-
-
-
Содержание SD3 Series
Страница 1: ...R FATEK AUTOMATION CORP Instruction Manual AC SERVO MOTOR and SERVO AMPLIFIER SD3 Series...
Страница 6: ...6 MEMO SD3 Series Instruction Manual...
Страница 52: ...32 MEMO 2 Specifications SD3 Series Instruction Manual...
Страница 92: ...40 MEMO 3 Preparation SD3 Series Instruction Manual...
Страница 292: ...48 MEMO SD3 Series Instruction Manual 6 Operation...
Страница 338: ...46 MEMO SD3 Series Instruction Manual 7 Tuning...
Страница 362: ...24 MEMO 8 Troubleshooting SD3 Series Instruction Manual...
Страница 395: ...MEMO SD3 Series Instruction Manual...
Страница 396: ...R...