BATTERY AND CHARGER
Read section A and B completely prior to operation or repair of golf car
J-13
Continuity Check
Before attempting to perform a continuity check, disconnect the battery charger from both AC
and DC power sources.
To check for continuity, set the DVOM (digital volt ohm meter) to KQ setting and select “Continuity”. The
meter will give an audible signal when it detects continuity. If the meter does not have a continuity setting,
set the meter then to KQ, the meter will indicate “0” when continuity is detected (Ref Fig. J12).
Fig. J 12: Continuity Check
DIODE TEST PROCEDURE
Tool List
Qty. Required
DVOM --------------------------------------------------------- 1
To test the diode, disconnect the battery charger AC power cord. With the DVOM set at highest ohms
range available, place probes on diode as shown (Ref Fig. J14). A reading other than that shown
indicates the diode is bad, Replace as necessary.
COMPONENT REPLACEMENT
When replacing components, reinstall in reverse order of disassembly. Pay particular attention any
wiring that may have been disconnected, being sure to replace in original position.