Proline Prosonic Flow 93 PROFIBUS DP/PA
Technical data
Hauser
153
10.1.4
Output
Output signal
PROFIBUS DP interface:
• PROFIBUS DP in accordance with IEC 61158, galvanically isolated
• Profile Version 3.0
• Data transmission rate: 9.6 kBaud to 12 MBaud
• Automatic data transmission rate recognition
• Signal coding: NRZ code
• Bus address can be configured via miniature switches, via the local display (optional) or operating
program
PROFIBUS PA interface:
• PROFIBUS PA in accordance with IEC 61158 (MBP), galvanically isolated
• Profile Version 3.0
• Data transmission rate: 31.25 kBaud
• Current consumption: 11 mA
• Permitted supply voltage: 9 to 32 V
• Bus connection with integrated reverse polarity protection
• Error current FDE (Fault Disconnection Electronic): 0 mA
• Signal coding: Manchester II
• Bus address can be configured via miniature switches, via the local display (optional) or operating
program
Current output
Active/passive selectable, galvanically isolated, time constant selectable (0.05 to 100 s),
Full scale value adjustable, temperature coefficient typ. 0.005% o.f.s./°C, resolution: 0.5
μ
A
• Active: 0/4 to 20 mA, R
L
< 700
Ω
• Passive: 4 to 20 mA; supply voltage V
S
18 to 30 V DC; R
i
≥
150
Ω
Pulse/frequency output:
Active/passive selectable, galvanically isolated
• Active: 24 V DC, 25 mA (max. 250 mA during 20 ms), R
L
> 100
Ω
• Passive: open collector, 30 V DC, 250 mA
• Frequency output: full scale frequency 2 to 10000 Hz (f
max
= 12500 Hz), on/off ratio 1:1,
pulse width max. 2 s
• Pulse output: pulse value and pulse polarity selectable,
pulse width configurable (0.05 to 2000 ms)
Signal on alarm
PROFIBUS DP/PA
Status and alarm messages in accordance with PROFIBUS Profile Version 3.0
Current output:
Failsafe mode selectable (for example NAMUR recommendation NE 43)
Pulse/frequency output:
Failsafe mode selectable
Relay output:
De-energized by fault or power supply failure
Содержание Proline Prosonic Flow 93
Страница 2: ......
Страница 168: ...www endress com worldwide BA00076D 06 EN 13 10 71121236 FM SGML6 0 ProMoDo...