Technical data
Proline Prosonic Flow 93 PROFIBUS DP/PA
158
Hauser
10.1.8
Operating conditions: environment
Ambient temperature range
Transmitter
–20 to +60 °C (–4 to +140 °F)
Sensor
• Standard: –40 to +80 °C (–40 to +176 °F)
• Optional: 0 to +170 °C (+32 to +338 °F)
DDU18 sensor (accessories: sound velocity measurement)
–40 to +80 °C (–40 to +176 °F)
DDU19 sensor (accessories: wall thickness measurement)
–20 to +60 °C (–4 to +140 °F)
Connecting cable (sensor/transmitter)
• Standard (PVC): –20 to +70 °C (–4 to +158 °F)
• Optional (PTFE): –40 to +170 °C (–40 to +338 °F)
!
Note!
• It is permitted to insulate the sensors mounted on the pipes.
• Mount the transmitter in a shady location and avoid direct sunlight, particularly in warm climatic
regions.
Storage temperature
The storage temperature corresponds to the ambient temperature range.
Degree of protection
Transmitter
IP 67 (NEMA 4X)
Sensor
IP 68 (NEMA 6P)
DDU18 sensor (accessories: sound velocity measurement)
IP 68 (NEMA 6P)
DDU19 sensor (accessories: wall thickness measurement)
IP 67 (NEMA 4X)
Shock and vibration resistance
According to IEC 68-2-6
Electromagnetic compatibility
(EMC)
Electromagnetic compatibility (EMC requirements) according to IEC/EN 61326 "Emission to
class A requirements" and NAMUR Recommendation NE 21/43.