Installation
Proline Prosonic Flow 93 PROFIBUS DP/PA
30
Hauser
3.7
Mechanical preparation
The way in which the sensors are secured differs on account of the pipe nominal diameter and the
sensor type. Depending on the type of sensor, users also have the option of securing the sensors with
strapping bands or screws such that they can be later removed, or permanently fixing the sensors in
place with welded bolts or welded retainers.
Overview of possible ways to secure the various sensors:
3.7.1
Mounting the sensor holder with U-shaped screws
• For mounting on a pipe with a nominal diameter of DN
≤
32 (1¼")
• For sensors: Prosonic Flow 93P (DN 15 to 65 / ½ to 2½")
Procedure
1.
Disconnect the sensor from the sensor holder.
2.
Position the sensor holder on the pipe.
3.
Put the U-shaped screws through the sensor holder and slightly lubricate the thread.
4.
Screw nuts onto the U-shaped screws.
5.
Set the holder to the exact position and tighten the nuts evenly.
#
Warning!
Risk of damaging plastic or glass pipes if the nuts of the U-shaped screws are tightened too
much! The use of a metal half-shell is recommended (on the opposite side of the sensor) when
working with plastic or glass pipes.
A0011524
Fig. 19:
Mounting the Prosonic Flow P sensor holder (DN 15 to 65 / ½ to 2½") with U-shaped screws
Prosonic Flow
For the measuring range
Pipe nominal
diameter
Secured by
93P
DN 15 to 65 (½ to 2½")
DN
≤
32 (1¼")
Sensor holder with U-shaped screws
DN
>
32 (1¼")
Sensor holder with strapping bands
93P
DN 50 to 4000 (2 to 160")
DN
≤
200 (8")
Strapping bands (medium nominal
diameters)
Welded bolts
DN
>
200 (8")
Strapping bands (large nominal diameters)
Welded bolts
93W
DN 50 to 4000 (2 to 160")
DN
≤
200 (8")
Strapping bands (medium nominal
diameters)
Welded bolts
DN
>
200 (8")
Strapping bands (large nominal diameters)
Welded bolts
Insertion version