Installation
Proline Prosonic Flow 93 PROFIBUS DP/PA
34
Hauser
3.7.5
Mounting the welded bolts
When mounting on a pipe with a nominal diameter of DN 50 to 4000 (2 to 160")
For sensors:
• Prosonic Flow 93P (DN 50 to 4000 / 2 to 160")
• Prosonic Flow 93W
Procedure
The welded bolts must be fixed at the same installation distances as the mounting bolts with
strapping bands. The following sections explain how to the align the mounting bolts depending on
the type of mounting and the measurement method:
• Prosonic Flow P (DN 50 to 4000 / 2 to 160"), Clamp-on
– Installation for measurement via one traverse
– Installation for measurement via two traverses
• Prosonic Flow W, Clamp-on
– Installation for measurement via one traverse
– Installation for measurement via two traverses
The sensor holder is secured with a retaining nut with a metric ISO M6 thread as standard. If you
want to use another thread to secure the sensor holder, you must use a sensor holder with a
removable retaining nut (order number: 93WAx - xBxxxxxxxxxx).
A0001111
Fig. 24:
Use of welded bolts
1
Welding seam
2
Retaining nut
3
Hole diameter max. 8.7 mm (0.34")
M6
50
1
2
3
1