6.
Project the middle line to the back of the pipe and draw it on.
A0001126
Fig. 49:
Installing the measuring sensors, steps 5 and 6
7.
Mark the drillhole on the middle line on the back of the pipe.
8.
Cut out the second drillhole and prepare the holes for welding the sensor holders, (deburr,
clean, etc.).
A0001127
Fig. 50:
Installing the measuring sensors, steps 7 and 8
9.
Insert the sensor holders into the two drillholes. To adjust the weld-in depth, you can fix both
sensor holders with the special tool for insertion depth regulation (optional) and then align
using the tie rod. The sensor holder must be flush with the inner side of the pipe.
10. Spot-weld both sensor holders.
!
Note!
To align the tie rod, you have to screw two guide bushings into the sensor holders.
A0001128
Fig. 51:
Installing the measuring sensors, steps 9 and 10