background image

 

 

 

 

 

 

 

 

 

  

 

 

MGS-401 Entrance Monitor 

for Commercial & Industrial Applications 

 

 

Fixed Gas Detection 

P/N: 1100-2527 

Revision 1.0 

User 

Manual

 

Содержание MGS-401

Страница 1: ...MGS 401 Entrance Monitor for Commercial Industrial Applications FixedGasDetection P N 1100 2527 Revision 1 0 User Manual...

Страница 2: ...charach com SERVICE POLICY MSA Bacharach Inc maintains a service facility at the factory Some MSA Bacharach distributors agents may also have repairfacilities however MSA Bacharach assumes no liabilit...

Страница 3: ...ts of this manual for important information on the operation and maintenance of the instrument 1 2 Conventions 1 2 1 Iconography Alert Icon Description WARNING Potentially hazardous situation which if...

Страница 4: ...lications Make sure the device is not located in areas that contain a flammable mixture of gas and air Otherwise an explosion can occur The device is not intrinsically safe Do not use the device in ar...

Страница 5: ...nce Monitor is but one piece of a complete gas detection system MGS 400 Series Gas detectors in the monitored area can signal via digital bus relays and or audible and visual output The digital Modbus...

Страница 6: ...de 6560 ft 2000 M Communications RS485 Modbus RTU Client for Gas Detectors RS485 Modbus RTU Server for BMS Visual Audible Signals Integrated high output visual strobe Integrated high output audible al...

Страница 7: ...er Manual 2 4 Front Panel Figure 2 4 Front Panel Layout Front Panel Description 1 Integrated visual alarm in bezel 2 Controller Power Fault LEDS 3 Mute alarm button 4 80dB Alarm 5 NPT Cable Glands x2...

Страница 8: ...2 5 MGS 401 Under Lid Connections and Configuration Component Description 1 24VAC DC Input Output 2 Modbus to Gas Detectors 3 Modbus to BMS 4 Remote Silence Alarm Input 5 Forced Alarm Input 6 Aux Buz...

Страница 9: ...ea where the MGS family gas detection instrument s is installed Failure to follow these warnings can result in serious bodily injury or death 3 2 Preliminary Inspection The MGS 401 Entrance Monitor ha...

Страница 10: ...ductors used to supply mains meet all local electrical safety codes Failure to follow these warnings can result in serious bodily injury or death Locate the 24VAC DC power input terminal block Item 1...

Страница 11: ...connected is a normally open connection The pushbutton in a remote location is used for personnel to silence the audible alarm momentarily with visual alarms still activated The audible alarm will ree...

Страница 12: ...configure the BMS Modbus Server settings when use with higher level controls Please refer to Modbus best practice when making these choices It is important ALL of the following instrument settings co...

Страница 13: ...ermination Please refer to Modbus best practice when making these choice The default is Not Enabled or OFF 2 Bank 2 Switches 2 and 3 are used to configure the number of sensors the MGS 401 is expectin...

Страница 14: ...x Head screws in and X pattern from top left to lower right upper right to lower left and then the remaining center top and bottom screws Torque all screws to 15 to 20 lbf in 1 5 to 2 0 Nm 5 Power Up...

Страница 15: ...m the MGS 401 Entrance Monitor will display that information on the LCD and respond with audible and visual alarms configured relay response and other countermeasures that are connected or configured...

Страница 16: ...he Silence button on the MGS 401 front panel 3 consecutive times within 3 seconds The System screen will show some of the configuration of the MGS401 In addition it will display any MGS 401 Fault Code...

Страница 17: ...MGS 401 User Manual 7 Modbus Map...

Страница 18: ...MGS 401 User Manual...

Страница 19: ...y in its original packing if possible as MSA Bacharach cannot be held responsible for any damage incurredduring shipping to our facility Location Contact Information Shipping Address United States Pho...

Отзывы: