Firmware V3.13
21.04.2021
109/466
Switch-on interval
The interval for the frame and pane heater is 10 minutes. For a run time of 10%, the frame heater switches ON
for 1 minute and OFF for 9 minutes.
Defrost
The frame heater is switched off during a defrost.
5.15 Compressor control via consumers
ATTENTION
Damage to equipment and goods!
Damage may be sustained by the merchandise or systems if this
mode is set on the pack controller. The VS 3010 BS/VS 300 operating mode compressor control is not
designed for use together with the case controller, see chapter
.