Firmware V3.13
21.04.2021
101/466
Switch-on
Up to 7 control times for automatic restarting of the counter can be set on an internal timer. The same 230 V
input is usable as an external input for setpoint toggling, in which case the on-off function will not be available.
The counter is switched on either by a voltage pulse applied to digital Input 2 or by the control times. The
transisitor output (terminals 91/92/93) is set to 24 V.
Switch-off
As with manual shutdown, all controlled functions are switched off by the voltage pulse applied to digital Input 2
(terminals D21/D22). The transisitor output (terminals 91/92/93) is set to 0 V.
DANGER
Warning - hazardous electrical voltage! Danger of electric shock! BEFORE and AFTER
connection it must checked that the 24 V DC transistor outputs are
off load
! The controller and
connected voltage carrying components remain supplied with power!
Counter shutdown can be activated via digital Input 2 (terminals D21/D22, factory setting). This
requires digital Input 2 to be set as AUTO ACTU. (menu 6-2-4) for the switch on/off function to be
available.
Parameters of the internal restart time are displayed and can be adjusted when setpoint toggle is set to
”INT” or ”---” (see Screen 3-3 in the UA 141 menu structure).
Содержание Case Controller UA 4 E Series
Страница 23: ...Firmware V3 13 21 04 2021 23 466 For more details see chapter Operation UA 4xx E...
Страница 135: ...Firmware V3 13 21 04 2021 135 466 Exit the menu by tapping the ESC button twice...
Страница 157: ...Firmware V3 13 21 04 2021 157 466 Connection diagram UA 400 E CC One zode controller and two zone controller...
Страница 158: ...Firmware V3 13 21 04 2021 158 466 Anschlussbild UA 401 E CC One zode controller...
Страница 207: ...Firmware V3 13 21 04 2021 207 466...
Страница 216: ...Firmware V3 13 21 04 2021 216 466 SENSORS POS XXXXX Entry Default 5K3A1 Temperature range 0 100 C...
Страница 277: ...Firmware V3 13 21 04 2021 277 466...
Страница 364: ...Firmware V3 13 21 04 2021 364 466 MODE POS XXXXX Entry Default Fixed run time Enthalpy ctrl rtm...