63
SPX advanced – description of parameters
SPX ADVANCED APPLICATION MANUAL
SVCH0203—October 2017 www.eaton.com
Code
ID
Parameter
Notes
P1.3.5
500
0
5
10
15
20
25
30
35
40
0.
00
0.
38
0.
76
1.
14
1.
52
1.
90
2.
28
2.
66
3.
04
3.
42
3.
80
4.
18
4.
56
4.
94
5.
32
5.
70
6.
08
10 % S
0 % S
P1.3.6
502
Acceleration time 2 “accel time 2”
P1.3.7
503
Deceleration time 2 “decel”
P1.3.8
501
Acceleration/Deceleration ramp 2 shape “ramp 2 shape”
These ramp times and ramp shapes are used when the second ramp time is activated
by digital input “Acc/Dec Time Sel”
P1.3.9
1257
Inching ramp “Inching Ramp”
This parameter defines acceleration and deceleration times when inching is active.
Inching function will start the drive to reference without additional start command
regardless of control place. Inching function requires enabling from digital input before
command is accepted. Inching is also disabled if there is a start command active on
the active control place.
Other parameters for inching:
•
Parameter: Inching reference 1
•
Parameter: Inching reference 2
•
Digital input selection: Enableinching
•
Digital input selection: inching 1
•
Digital input selection: inching 2
P1.3.10
401
Reduction of acceleration and deceleration times
Acceleration and deceleration times can be reduced with the input signal.
Input signal level zero means ramp times set by parameters. Maximum level equals
one tenth of the value set by parameter.
Ramp Time Factor
Adjust
Input [%]
100 %
10 %
Figure 5-3 . 10 % S ramp with 3 s ramp time when
reference set toto zero at 25 Hz