6
SPX Advanced application – monitoring values
SPX ADVANCED APPLICATION MANUAL
SVCH0203—October 2017 www.eaton.com
3.1.1 Monitoring values 2
Table 2 . Monitoring values 2
Code
Parameter
Unit
Form
ID
Description
V7.25.1
Current
A
Varies
1113
Unfiltered motor current
V7.25.2
Torque
%
#,#
1125
Unfiltered motor torque
V7.25.3
DC Voltage
V
#
44
Unfiltered DC link voltage
V7.25.4
Application status word
43
V7.25.5
Shaft frequency
Hz
#,##
1124
Unfiltered
V7.25.6
Output power
kw
Varies
1508
Unfiltered electrical power
V7.25.7
Measured temperature 1
Cº
#,#
50
4 s filtering.
V7.25.8
Measured temperature 2
Cº
#,#
51
4 s filtering.
V7.25.9
Measured temperature 3
Cº
#,#
52
4 s filtering.
V7.25.10
Measured temperature 4
Cº
#,#
69
4 s filtering.
V7.25.11
Measured temperature 5
Cº
#,#
70
4 s filtering.
V7.25.12
Measured temperature 6
Cº
#,#
71
4 s filtering.
V7.25.13
ABS Encoder revolutions
r
#
55
V7.25.14
ABS Encoder position
#
54
V7.25.15
Step response
Hz
#,##
1132
V7.25.16
Actual power factor
#,###
68
V7.25.17
Flux current
%
#,#
72
V7.25.18
Regulator status
77
V7.25.19
Frequency delta
Hz/s
1847
V7.25.20
Data logger trigger word
97
Different status bits to help diagnostic with data logger.
V7.25.21
Encoder 2 frequency
Hz
53
V7.25.22
Operation hours
h
1856
V7.25.23
Status word 2
89
V7.25.24
Rotor flux
%
#,#
1158
3.1.2 FieldBus monitoring values
Table 3 . FieldBus monitoring values
Code
Parameter
Unit
Form
ID
Description
V7.26.1
FB Control word
1160
V7.26.2
FB Speed reference
875
V7.26.3
FB Status word
65
V7.26.4
FB Actual speed
865
V7.26.5
FB Torque reference
%
#,#
1140
Default control of FB PD 1
V7.26.6
FB Limit scaling
%
#,##
46
Default control of FB PD 2
V7.26.7
FB Adjust reference
%
#,##
47
Default control of FB PD 3
V7.26.8
FB Analog output
%
#,##
48
Default control of FB PD 4
V7.26.9
FB Motor current
A
#,#
45
Motor current (drive independent) given with one decimal point
V7.26.10
Fault word 1
1172
V7.26.11
Fault word 2
1173
V7.26.12
Warning word 1
1174
V7.26.13
AuxStatusWord
1163
V7.26.14
FB Power reference
1703
V7.26.15
Last active fault
37
V7.26.16
AuxControlWord
1161
V7.26.17
Din status word
56
V7.26.18
Din status word 2
57
V7.26.19
MC Status
64
V7.26.20
Last active warning
74
V7.26.21
Shaft rounds
1170