39
SPX Advanced application – parameter list
SPX ADVANCED APPLICATION MANUAL
SVCH0203—October 2017 www.eaton.com
4.12.12 Encoder fault
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.12.12.1 Encoder fast Hz limit
0.00
320.00
Hz
1801
P1.12.12.2 Fast time limit
0.00
32.00
s
1805
P1.12.12.3 Iq Fault limit
0
300
%
1800
4.12.13 Cold weather
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.12.13.1 Cold weather enable
0
1
0
1490
0=Disable
1=Enable
P1.12.13.2 Cold weather voltage
0
20.00
s
2.00
1491
P1.12.13.3 Cold weather timeout
0
10
Min
5
1492
Timeout
4.12.14 Thermal derate
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.12.14.1 Derate enable
0
1
0
1680
0=Disable
1=Enable
P1.12.14.2 Derate unit temp
–10
90
C
85
1681
P1.12.14.3 Derate %
0
100.0
%
50.0
1682
P1.12.14.4 Derate warning
0
1
1
1683
0=Disable
1=Enable
4.13 Fieldbus parameters
Table 36 . Fieldbus parameters
Code
Parameter
Min
Max
Unit
Default
ID
Note
P1.13.1
Fieldbus min scale
0.00
320.00 Hz
0.00
850
P1.13.2
Fieldbus max scale
0.00
320.00 Hz
0.00
851
P1.13.3
Fieldbus process data out 1
selection
0
10000
1
852
Choose monitoring data with parameter ID
Def: Output frequency
P1.13.4
Fieldbus process data out 2
selection
0
10000
2
853
Def: Motor speed
P1.13.5
Fieldbus process data out 3
selection
0
10000
3
854
Def: Motor current to FB
P1.13.6
Fieldbus process data out 4
selection
0
10000
4
855
Def: Motor torque
P1.13.7
Fieldbus process data out 5
selection
0
10000
5
856
Def: Motor power
P1.13.8
Fieldbus process data out 6
selection
0
10000
6
857
Def: Motor voltage
P1.13.9
Fieldbus process data out 7
selection
0
10000
7
858
Def: DC-Link voltage
P1.13.10
Fieldbus process data out 8
selection
0
10000
37
859
Def: Last active fault
P1.13.11
Fieldbus process data in 1
selection
0
10000
1140
876
Choose controlled data with parameter ID.
Def: FB Torque reference
P1.13.12
Fieldbus process data in 2
selection
0
10000
46
877
Def: FB Limit scaling
P1.13.13
Fieldbus process data in 3
selection
0
10000
47
878
Def: FB Adjust reference
P1.13.14
Fieldbus process data in 4
selection
0
10000
48
879
Def: FB Analog output.
P1.13.15
Fieldbus process data in 5
selection
0
10000
0
880
Choose controlled data with parameter ID