SiUS342303E
Field Setting from Outdoor Unit
Part 5 Field Settings and Test Operation
190
2.4.2 Overview of Setting Mode (Mode 2)
This overview shows the available settings by using the press buttons on the outdoor unit PCB.
No.
1
Item
Description
7 segment
display
Description
7 segment
display
Range
SEG
1
SEG
2
SEG
3
SEG
1
SEG
2
SEG
3
0
COOL/HEAT
selection
Several systems as 1 zone change
over COOL/HEAT:
INDIVIDUAL:
VRV
indoor unit or
A-B-C input set mode.
MASTER: System is the
COOL/HEAT master unit.
SUB: System is not a
COOL/HEAT master.
2.
0
0
Individual
Unified Master
Unified Sub
0
1
2
1
COOL/HEAT
unified address
Used to make address setting for
unified cooling/heating operation.
2.
0
1
Address:
0
~
31
3
0
1
2
Low noise/
demand address
Used to make address setting for
low noise/demand operation.
2.
0
2
Address:
0
~
31
3
0
1
4
Phased
installation
setting
Used to make setting for phased
installation.
2.
0
4
Normal installation
Single module to dual module
installation
0
1
5
Indoor fan forced
H
Used to force the fan of indoor unit
to H tap.
2.
0
5
Normal operation
Indoor fan H
0
1
6
Forced
thermostat
Used to force all indoor units to
operate forced thermostat ON.
2.
0
6
Normal operation
Forced thermostat ON
0
1
8
Te setting
(Cooling
operation)
Used to make setting of targeted
evaporating temperature for
cooling operation.
2.
0
8
Auto
6°C (43°F)
7°C (45°F)
8°C (46°F)
9°C (48°F)
10°C (50°F)
11°C (52°F)
0
2
3
4
5
6
7
9
Tc setting
Used to make setting of targeted
condensing temperature for
heating operation.
2.
0
9
Auto
41°C (106°F)
43°C (109°F)
46°C (115°F)
0
1
3
6
11
Eco setting is available from an external input.
When this configuration is set, it is not possible to turn
the Eco refrigerant control ON/OFF using the remote
controller. Also, depending on the settings, low noise
operation or demand operation may not be performed
using the external control adaptor.
2.
1
1
Unavailable
Eco setting by low noise level
input
Eco setting by demand input
0
1
2
12
External low
noise setting/
demand setting
Used to receive external low noise
or demand signal.
2.
1
2
Input LNO/DE
OFF
ON
0
1
13
AIRNET address Used to set address of AIRNET.
2.
1
3
Address:
0
~
63
6
0
3
16
Heat pump
lockout 1
Used for heat pump lockout.
2.
1
6
OFF
ON
0
1
18
High ESP setting
FAN
Fan high static pressure setting
2.
1
8
OFF
ON
0
1
20
Additional
refrigerant
charge
Used to perform additional
refrigerant charging operation
(compressor operation).
2.
2
0
OFF
Refrigerant charging ON
0
1
21
Refrigerant
recovery and
vacuuming
Used to set the system to
refrigerant recovery mode (without
compressor run).
2.
2
1
Refrigerant recovery
OFF
ON
0
1
22
Automatic night-
time low noise
operation
Automatic night-time low noise
operation.
Time for the operation is subject to
the start and end time settings.
2.
2
2
OFF
Level 1
Level 2
Level 3
0
1
2
3
23
Used to set Eco mode invalid.
When this configuration is set, it is not possible to turn
the Eco mode ON/OFF using the external control
adaptor.
2.
2
3
Valid
Invalid for cooling
Invalid for heating
Invalid for cooling and heating
0
1
2
3
Содержание VRV EMERION RXYQ-AATJA
Страница 1: ...Service Manual Heat Pump 60 Hz RXYQ AATJA 208 230 V RXYQ AAYDA 460 V SiUS342303E...
Страница 380: ...Check SiUS342303E 373 Part 6 Service Diagnosis Reference Reference CHECK 7 Refer to page 379 CHECK 8 Refer to page 380...
Страница 405: ...SiUS342303E Wiring Diagrams Part 7 Appendix 398 RXYQ72 96 120 144 168 192 216 240AAYDA C 2D140769B...
Страница 406: ...Wiring Diagrams SiUS342303E 399 Part 7 Appendix 1 2 Indoor Unit FXFQ07 09 12 15 18 24 30 36 48TVJU 3D086460B...
Страница 407: ...SiUS342303E Wiring Diagrams Part 7 Appendix 400 BYCQ125BGW1 Self Cleaning Decoration Panel for FXFQ TVJU 3D076375A...
Страница 410: ...Wiring Diagrams SiUS342303E 403 Part 7 Appendix FXEQ07 09 12 15 18 24PVJU 3D098557A...
Страница 411: ...SiUS342303E Wiring Diagrams Part 7 Appendix 404 FXDQ07 09 12 18 24MVJU C 3D050501C...
Страница 413: ...SiUS342303E Wiring Diagrams Part 7 Appendix 406 FXMQ07 09 12 15 18 24 30 36 48 54PBVJU 3D093209B...
Страница 416: ...Wiring Diagrams SiUS342303E 409 Part 7 Appendix FXHQ12 24 36MVJU 3D048116C...
Страница 417: ...SiUS342303E Wiring Diagrams Part 7 Appendix 410 FXAQ07 09 12 18 24PVJU 3D075354F...
Страница 423: ...SiUS342303E Wiring Diagrams Part 7 Appendix 416 1 3 2 Energy Recovery Ventilator VAM Series VAM300 470 600GVJU 3D073269D...
Страница 424: ...Wiring Diagrams SiUS342303E 417 Part 7 Appendix VAM1200GVJU 3D073270D...