5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
624
1
00:00:AA:BB:CC:DD
1.1.1.1
345
Static
1
00:09:AA:BB:CC:EE
1.1.1.1
345
Static
1
00:EA:08:CA:16:45
1.1.1.1
345
Learned
Display Parameters
Tenant ID
Virtual Subnet lD (VSID).
Tenant MAC
MAC address of a host or tenant system.
NVE
IP address of NVE if the tenant system is behind the remote NVE. This
is valid for the remote tenant system, otherwise it is blank..
Interface
Access interface on which the MAC entry is learned or configured. This
valid for the tenant system on the local access interface, otherwise it is
blank.
Applflndex
Internal access or tunnel port handle.
Entry Type
Configured or learned.
6-56
show vxlan
This command is used to display the configuration and status of one or more VXLAN VNs. The command
also shows information regarding allowed limits and statistics.
show vxlan [vnid]
Parameters
vnid
(Optional) Indicates VXLAN VNID.
Default
The default is None.
Command Mode
Privileged EXEC
Example
(Routing)(Config)#show vxlan
VXLAN Admin Mode................................. Enable
Destination UDP Port............................. 4789
Maximum Allowed Limits or Table Sizes
------------------------------------------------------------
Tenant Table Size................................ 1024
Access Ports Table Size.......................... 2048
Содержание 5000 Series