5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
613
The
no
command is used to disable the NVGRE mode on the switch. It also clears the switch of all
existing NVGRE configurations, including all NVGRE tunnels, tenants, tenant VLAN associations, and
configured forwarding entries.
Note:
The NVGRE mode and VXLAN mode are mutually exclusive modes. That is, the NVGRE mode
cannot be enabled on the switch if the VXLAN mode is enabled. Rather, the VXLAN mode must be
disabled before enabling the NVGRE mode.
nvgre enable
no nvgre enable
Parameters
None
Default
The default is Disabled.
Command Mode
Global Config
6-43
nvgre source-interface
This command is used to specify a VXLAN source interface.
nvgre vxlan source-interface loopback loopback-id
no nvgre vxlan source-interface loopback loopback-id
Parameters
loopback-id
Enter Loopback Interface ID (0-63).
Default
The default is None.
Command Mode
Global Config
6-44
vxlan enable
This command is used to enable the VXLAN mode on the switch. The VXLAN mode, which is disabled by
default, must be enabled before any VXLAN configuration can be performed on the switch.
Note:
The NVGRE mode and VXLAN mode are mutually exclusive modes. That is, the VXLAN mode
cannot be enabled on the switch if the NVGRE mode is enabled. Rather, the NVGRE mode must be
disabled before enabling the VXLAN mode.
The
no
command is used to disable the VXLAN mode on the switch. It also clears the switch of all
existing VXLAN configurations, including all VXLAN tunnels, tenants, tenant VLAN associations, and
configured forwarding entries.