5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
184
Command Mode
Global Config
5-42
logging cli-command
This command is used to enable the CLI command logging feature, which in turn makes the D-LINK OS
software capable of logging all the CLI commands issued on the system, with those commands being
stored in a persistent log. The
show logging persistent
command is used to show the stored history of
CLI commands.
The
no
command is used to disable the CLI command logging feature.
logging cli-command
no logging cli-command
Parameters
None
Default
The default is Disable.
Command Mode
Global Config
5-43
logging console
This command is used to enable logging on to the console. The user can specify the
severitylevel
value
as either an integer from 0 to 7 or in a symbolic fashion through the use of one of the following keywords:
emergency
(0),
alert
(1),
critical
(2),
error
(3),
warning
(4),
notice
(5),
info
(6), or
debug
(7).
The
no
command is used to disable logging on to the console.
logging console [severitylevel]
no logging console
Parameters
severitylevel
(Optional) Select the Logging Severity Level.
Default
The default is Enable.