5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
387
Asymmetric Flow Control Commands
Configure settings for symmetric, asymmetric or no flow control. Asymmetric
flow control allows the switch
to respond to received PAUSE frames—port is unable to generate PAUSE frames. Symmetric flow
control allows the switch to respond and generate MAC control PAUSE frames.
5-317 flowcontrol
Enable or disable symmetric or asymmetric flow control. Asymmetric disables Tx Pause, enabling only Rx
Pause.
No
command disables the symmetric and asymmetric flow control.
flowcontrol {symmetric | asymmetric}
no flowcontrol
Parameters
symmetric
Enable Symmetric flow control.
asymmetric
Enable Asymmetric flow control.
Default
The default is Disabled.
Command Mode
Global Config
5-318 show flowcontrol
Display the IEEE 802.3 Annex 31B flow control settings and status for all or specific interfaces. In addition,
it displays 802.3 Tx and Rx pause counts.
show flowcontrol [slot/port]
Parameters
slot/port
Enter an interface in slot/port format.
Default
The default is None.
Command Mode
Privileged EXEC