5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
285
Display the diagnostic information of the SFP. The values are derived from the SFP‘s A2 (Diagnostics)
table using the l
2
C interface.
show fiber-ports optical-transceiver {all | slot/port}
Parameters
all
Enter all for all interfaces.
slot/port
Enter an interface in slot/port format.
Default
The default is None.
Command Mode
Privileged EXEC
Example
The following is a CLI display output example.
(Routing)#show fiber-ports optical-transceiver all
Link
Link
Nominal
Length Length
Bit
50um
62.5um
Rate
Port Vendor Name
[m]
[m]
Serial Number
Part Number [Mbps] Rev
Compliance
----- --------
----- ------ ------------
---------- ----------
----------
0/1
D-LINK
8
3
SA011G4000005
DEM-431XT
10300
10GBase-SR
0/2
D-LINK
8
3
SA011G4000005
DEM-431XT
10300
A
10GBase-SR
0/3
D-LINK
8
3
SA011G4000005
DEM-431XT
10300
C1
10GBase-SR
0/49
Volex Inc.
0
0
26201134400002
VAHS-26-0256 10300
x1
40GBase-CR4
(Routing)#show fiber-ports optical-transceiver 0/49
Link
Link
Nominal
Length Length
Bit
50um
62.5um
Rate
Port Vendor Name
[m]
[m]
Serial Number
Part Number [Mbps] Rev
Compliance
----- --------
----- ------ ------------
---------- ----------
----------
0/49
Volex Inc.
0
0
26201134400002
VAHS-26-0256 10300
x1
40GBase-CR4
Display Parameters
Port
Indicates the port interface.
Temp
Internally measured transceiver temperature.
Содержание 5000 Series