5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
24
This command is used to show the configuration settings associated with the network interface of the
switch. Please note that the network interface is the logical interface that is used to provide the switch
with in-band connectivity via any of the switch's front panel ports. Also note that the configuration of the
front panel ports through which traffic is switched or routed is not affected by t
he configuration parameters
associated with the switch's network interface. Regardless of whether or not any member ports are up,
the network interface is always considered to be up; as such, the
show network
command will always
display the
Interface Status
as up.
show network
Parameters
None
Default
The default is None.
Command Mode
Global Config
Example
The following provides an example of a CLI display output for the network port.
(Switching)#show network
Interface Status.......................
Up
IP Address.............................
10.250.3.1
Subnet Mask............................
255.255.255.0
Default Gateway........................
10.259.3.3
IPv6 Administrative Mode...............
Enabled
Burned In MAC Address..................
00:05:64:2F:0D:E5
MAC Address Type.......................
Burned In
Configured IPv4 Protocol...............
None
Configured IPv6 Protocol...............
None
IPv6 AutoConfig Mode...................
Disabled
Management VLAN ID.....................
1
Display Parameters
Interface Status
Indicates the network interface status; it is always considered to be “up”.
IP Address
Indicates the IP address (default: 10.90.90.90/8) for the given interface.
Subnet Mask
Indicates the IP subnet/mask for the given interface.
Default Gateway
Indicates the default gateway for the given IP interface.
IPv6 Administrative Mode
Indicates whether the IPv6 Administrative Mode is enabled or disabled.
IPv6 Address/Length
Indicates the IPv6 address and length.
IPv6 Default Router
Indicates the IPv6 default router address.
Burned In MAC Address
Indicates the burned in MAC address utilized for in-band connectivity.