5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
839
8-46
show ipv6 route hw-failure
Displays the routes for which failure to be added to the hardware occurred due to hash errors or a table
full condition.
show ipv6 route hw-failure
Parameters
None
Default
The default is None.
Command Mode
Privileged EXEC
Example
The following is an example of the command output.
(Routing)#show ipv6 route connected
IPv6 Routing Table - 2 entries
Codes: C - connected, S - static, 6To4 - 6to4 Route, B - BGP Derived
O - OSPF Intra, OI - OSPF Inter, OE1 - OSPF Ext 1, OE2 - OSPF Ext 2
ON1 - OSPF NSSA Ext Type 1, ON2 - OSPF NSSA Ext Type 2, K - kernel
P - Net Prototype
C
2001::/128 [0/0]
via ::, 0/1
C
2005::/128 [0/0]
via ::, 0/2
(Routing)#show ipv6 route hw-failure
IPv6 Routing Table - 4 entries
Codes: C - connected, S - static, 6To4 - 6to4 Route, B - BGP Derived
O - OSPF Intra, OI - OSPF Inter, OE1 - OSPF Ext 1, OE2 - OSPF Ext 2
ON1 - OSPF NSSA Ext Type 1, ON2 - OSPF NSSA Ext Type 2, K - kernel
P - Net Prototype
P
3001:: /64 [0/1]
via 2001::4, 00h:00m:04s, 0/1 hw-failure
P
3001:0:0:1::/64 [0/1]
via 2001::4, 00h:00m:04s, 0/1 hw-failure