Peripheral Devices
476
9836 3521 01
For the values spindle number, bolt number and program number the setting in the field width in the
reporter sets the number of digits to use, it is padded with 0‟s to the left to reach this number of digits. If
width is empty the actual number of digits in the result value is used.
The string sent as Maintenance Sequence is left aligned and padded with spaces to reach 30 characters.
If the total numbers of characters selected are more than 30 only the first 30 (counted from left) will be
sent. In this case an event will be issued to inform the user of the occurrence.
Example:
With the following settings in the reporter:
Result variable
Order:
Width:
Station name
1
6
Spindle number
2
3
Bolt number
Program number
4
2
Station name =
Test1234
Spindle Number =
12
Bolt Number =
17
Program Number =
21
The maintenance sequence will be “
Test12012-21
”
8.11.5.3
Possible error codes
Value sent
Meaning
Corresponding PowerMACS error
1
MD-max
THM, torque high monitoring
2
MD-min
TLM, torque low monitoring
3
WI-max
AHM, angle high monitoring
4
WI-min
ALM, angle low monitoring
5
Angle different
DEV1M, DEV2M or DEV, Deviation in interval 1 or 2 to high during
monitoring or Deviation to high from check. Set if any of these errors are
present.
6
Gradient max
TRH, Torque rate to high from check.
7
Gradient min
TRL, Torque rate to low from check.
8
Draft1 max
TR1HM, torque rate 1 high monitoring
9
Draft1 min
TR1LM, torque rate 1 low monitoring
10
Draft2 max
TR2HM, torque rate 2 high monitoring
11
Draft2 min
TR2LM, torque rate 2 low monitoring
13
Not OK-Time
TIH or TIL, time high or low from check
Also TIR, time restriction
18
Not enough WI
AL, angle low from check
19
Self tap max
PVTH, post view torque too high from check
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...