Peripheral Devices
9836 3521 01
619
8.17.5.9 Sequence and Program, Step, Speed, Ramp down data
Syntax:
Program[
<
pgm name
>
].Step[
<
step no
>
].Speed.RampDown[
<
ramp
>
].
<
parameter
>
Sequence[
<
seq name
>
].Step[
<
step no
>
].Speed.RampDown[
<
ramp
>
].
<
parameter
>
<
pgm name
>
= The name of the program
<
step no
>
= Step number, 1..50
<
ramp
>
= Ramp number, 1..5
<parameter>
= See table below (and Step
– for a description)
<parameter>
Data type
Description
Start
Short integer
Defines the quantity to monitor as start condition.
Allowed values:
1. Torque
2. Angle
3. Current
4. Time
Level
Float
The trig level of the measured quantity.
Speed
Float
The new target speed.
Ramp
Float
The ramp to use when changing the speed.
Example:
Program[Pgm01].Step[1].Speed.RampDown[1].Start
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...