Tightening
344
9836 3521 01
6.5.4.18 Check Backlash angle (only available for Gauging)
Parameters
:
Backlash angle high, Backlash angle low
Function:
The backlash angle used in the step (measured by the last BCT step ran) is compared to
the limits
Backlash angle high and Backlash angle low
. Both or only one of the limits can
be programmed.
Result var:
"BCT A", "BCT A1", "BCT A2" (Backlash angle)
Alarms:
Backlash angle high (BAH) and Backlash angle low (BAL).
Trace
:
No limits are shown in trace.
6.5.4.19 Check external input (only available for Gauging)
Parameters
:
Digital Input, Signal Value
Function:
The selected
Digital Input
is compared to the
Signal Value
at the end of the step, after the
over shoot time has passed.
The following digital signals are available for
Digital Input
:
Local DI 1, … Local DI 4
(the digital outputs directly on the TC)
PLC_DO
_1, … PLC_DO_10
(avalible as outputs in the PLC)
Possible
Signal Value
are
Low
or
High
Result var:
None
Alarms:
Step input not OK (NOKINPUT).
Trace
:
No limits are shown in trace.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...