Peripheral Devices
602
9836 3521 01
The first found step defines the control strategy of the program.
Step type
Defines Control Strategy as
DT2 - Run until Dyna-TorkTM, method 2
DT3 - Run until Dyna-TorkTM, method 3
TC - Run until Torque with Current Control
Torque Control.
AO - Run until Angle with overshoot compensation
PA - Run until Projected angle
– Run Torque-Angle with no stop
Angle Control.
All other step types
Undefined
Depending on the outcome of the Monitoring result and the Control strategy of the used program the result
for each bolt is indicated according to the following schemas:
Torque Control strategy:
TORQUE (Bolt T)
< ZDR
Low
OK
High
> Remove limit
ANG
L
E
(Bo
lt
A)
Low
Yellow
Yellow
Yellow
+
Red
Yellow
+
Red
Red
OK
Yellow
Green
Yellow
+
Red
Red
High
Red
Red
Red
Red
If a REHIT is detected (see below for how) then the
Yellow
+
Red
outputs are set.
Angle Control strategy:
TORQUE (Bolt T)
< ZDR
Low
OK
High
> Remove limit
ANG
L
E
(Bo
lt
A)
Low
Yellow
Yellow
+
Red
Yellow
+
Red
Yellow
+
Red
Red
OK
Yellow
+
Red
Green
Yellow
+
Red
Red
High
Red
Red
Red
Red
If a REHIT is detected (see below for how) then the
Yellow
+
Red
outputs are set.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...