Tightening
9836 3521 01
359
See the following example with Bolt 1 and Bolt 2. Bolt 1 fails in step 3 and 4. First failure Retry run on both
steps for all bolts:
1
2
3
4
5
6
7
8
9
10
11
12
CE
RE
-/-/-
-/-/-
9/1/-
9/1/-
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
Failing
synchronization
interval
Synch
Mark
Synch
Mark
3 Bolt transfer from state
RUNNING REPAIR to
RUNNING NORMAL
1 Bolt transfer from state
RUNNING NORMAL to
RUNNING REPAIR
2 Bolt transfer from state
RUNNING REPAIR to RUNNING
NORMAL to RUNNING REPAIR
Bolt 2 runs OK, but is ordered to Retry when bolt 1 fails:
1
2
3
4
5
6
7
8
9
10
11
12
CE
RE
-/-/-
-/-/-
9/-/-
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
Synch
Mark
Synch
Mark
2 Bolt 2 waits for bolt 1 to finish repair.
Retry ordered when repair ready. Run Retry
as configured in step 3
1 Bolt transfer from state
RUNNING NORMAL to
RUNNING REPAIR
3 Bolt 2 waits for bolt 1 to finish repair. Run Next
ordered when repair ready. Change state from
RUNNING REPAIR to RUNNING NORMAL.
When a bolt has reported that repair is ready, due to a CE step, the bolt will reenter state Running Normal
while waiting for the other bolts to finish. If any other bolt fails when running normal, reject management
will affect the bolt at CE. Retry and Terminate steps will be run as configured in the last step before the CE
step.
See the following example with Bolt 1 and Bolt 2. Bolt 1 fails in step 3 and 7. In step 3 First failure action is
Retry for all bolts. In step 7 First try action is Terminate for all bolts:
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...