Peripheral Devices
9836 3521 01
421
8.4.3
Operator Panel
To access the operator panel configuration window, add an operator panel device and double-click on it in
the system map.
Select the correct
MAC Id
for the Operator Panel. When a new Operator Panel device is added a simple
default configuration is provided.
Configure the Operator Panel by selecting the component you wish to edit (lamp, buzzer or button) in the
property grid on the right side or by clicking on the component in the operator panel image.
Once a component is selected configure the digital IO signal to connect to the component and additional
properties (flashing, duration etc.).
A special integer
Mode
signal is provided to use with LED displays to show the actual mode number
selected. Use the
DI_Manual
signal to override other devices mode selection.