6.5.3.8 Angle Difference
Parameters
: Use spindle limits, Max difference, Number of samples
Function
:
Supervises Angle channel 1 readings compared to Angle channel 2 readings. The
restriction requires two angle channels to be equipped on the spindle.
Select if you want to use the spindle‟s stored limits or configure your own limits (
Max
difference
– Maximum difference in degrees,
Number of samples
–
For how many
samples (milliseconds) Max difference is allowed).
If a angle double transducer protection is configured on the spindle this restriction will
replace that during the step, see Angle Double Transducer Check.
Diagram
:
None
Alarms
:
Double Angle Transducer Error (ADIFF)