Appendix
638
9836 3521 01
Code
Comp
Code
Type
Severity Event string
3701
401
Ext. com
Error
Received failed (port %d, info %d)
3702
402
Ext. com
Error
State machine error for send (port %d, state %d)
3703
403
Ext. com
Error
State machine error for receive (port %d, state %d)
3704
404
Ext. com
Error
Status from sio not OK (port %d, retcode %d)
3705
405
Ext. com
Error
Unknown protocol selected (port %d, protocol type %d)
3706
406
Ext. com
Error
Bad Checksum received (port %d, Checksum in tgm %d, calc.
Checkum %d)
3707
407
Ext. com
Error
Read telegram failed (TELWAY protocol, info %d)
3801
408
System
Error
EPH: Error when receiving (type=%d, d1=%d, d2=%d)
3802
409
System
Error
EPH: Error when sending (type=%d, d1=%d, d2=%d)
3811
420
Ext. com
Info
EPH: Connection established
3812
421
Ext. com
Error
EPH: Connection lost
3813
422
Setup
Error
EPH: Bad Data IP address, %d
3814
505
Ext. com
Error
EPH: Bad configuration of Barcode and VIN number
3815
506
Ext. com
Error
EPH: Station QO has not correct value: %d
3816
546
Ext. com
Error
EPH: Bad length of received TMU, (acctual = %d, expected =
%d)
3817
508
Ext. com
Error
EPH: No response from PLUS server
3818
509
Ext. com
Error
EPH: Wp.Id has bad layout (Length = %d)
3819
510
Ext. com.
Info
EPH: Connection to PLUS established as server
3820
511
Ext. com.
Info
EPH: Connection to PLUS established as client
3821
519
Ext. com.
Error
EPH: No TMU received from PLUS, NNEG received
3822
520
Ext. com.
Info
EPH: No TMU received from PLUS, No tightening shall be made
for sent barcode
3823
521
Ext. com.
Warning
EPH: No TMU received from PLUS, Barcode already used
3824
522
Ext. com.
Error
EPH: No TMU received from PLUS, telegram sent from TC
inconsistent
3825
523
Ext. com.
Warning
EPH: Problem in PLUS server, NNEG received in state Idle
3826
524
Ext. com.
Warning
EPH: No matching mode number for received TMU
3827
525
Ext. com.
Error
EPH: No SA found for mode number: %d
3828
526
Ext. com.
Error
EPH: SA has not correct value: %d
3829
529
Ext. com.
Warning
EPH: No TMU received from PLUS, Double tightening not
allowed
3830
530
Ext. com.
Error
EPH: No TMU received from PLUS, Id No unknown in PLUS
server
3831
547
Ext. com.
Error
EPH: No TMU received from PLUS, Bad layout of telegram
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...