Peripheral Devices
9836 3521 01
505
See chapter: Process data for a description of how the Process Data is laid out and how SEQ and LEN is
used.
Example:
To write the ten characters ID code "ABCDEFGHIJ" to the PLC input starting at address
2010 the following should be written to the fieldbus process data input:
0
0x48
CMD (MSB)
1
0x00
CMD (LSB)
2
0x00
Target Addr. (MSB)
3
0x0A
Target Addr. (LSB)
4
0x00
LEN (MSB)
5
0x0A
LEN (LSB)
6
0x41
A
7
0x42
B
8
0x43
C
9
0x44
D
10
0x45
E
11
0x46
F
12
0x47
G
13
0x48
H
14
0x49
I
15
0x4A
J