Appendix
650
9836 3521 01
Code
Comp
Code
Type
Severity Event string
5727
924
Check
Error
Step %d, Check: Time failed, Zone %d was never started
5728
925
Check
Error
Step %d, Check: T/T3 failed, Zone %d was was not finished
5729
926
Check
Error
Step %d, Check: Torque Rate calculation failed, Zone %d was
never started
5730
927
Setup
Error
Step %d, Res var have bad configuration. %d is not a valid cycle
data variable
5731
928
Setup
Error
Step %d, Check with identity %d has bad configuration
5732
929
Check
Error
Step %d, Check: Delta torque failed, Zone %d was never started
5733
930
Check
Error
Step %d, Check: Delta torque failed
5734
931
Check
Error
Step %d, Check: Delta torque. %f > %f
5735
932
Check
Error
Step %d, Check: Delta torque. %f < %f
5736
933
Setup
Error
Step %d has bad configuration, one or more paramters are
faulty, Step Type = %d
5737
938
Setup
Warning
Step %d, The step is syncronized since Wait for PLC to continue
is checked.
5738
939
Pos. reg
Info
Step %d, PosValid %d, Stored External Postion = %f
5739
940
Abs. pos
Info
Acctual Internal position = %d, Acctual External position = %f
5740
941
Setup
Error
Step %d, Store of position register not possible, Angle channel
does not exist
5741
942
Emergency
Error
The e-stop chain is broken somewhere between TC %d and the
primary TC (TC %d)
5742
943
Emergency
Error
E-stop is faulty. TC %d (station TC) is e-stopped, some other
TCs isn't
5743
944
Check
Error
Step %d, Check: Shut Off Torque failed, Zone %d was was not
finished
5744
945
Check
Error
Step %d, T1 Shunt Cal NOK. Shunt drift from last cal too high,
%f > %f
5745
946
Check
Error
Step %d, T2 Shunt Cal NOK. Shunt drift from last cal too high,
%f > %f
5746
947
Check
Error
Step %d, T1 Zero Offset comp NOK. Drift from last cal too high
%f > %f
5747
948
Check
Error
Step %d, T2 Zero Offset comp NOK. Drift from last cal too high
%f > %f
5748
949
Check
Error
Step %d, T1 Shunt Calibration NOK. Measured Shunt too low
%f < %f
5749
950
Check
Error
Step %d, T2 Shunt Calibration NOK. Measured Shunt too low
%f < %f
5750
951
Check
Error
Step %d, T1 Shunt Calibration NOK. Measured Shunt too high
%f > %f
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...