Set Up and Maintenance
9836 3521 01
153
4.6.6
Diagnostic page
The parameters located on the Diagnostic page specifies the limits of the zero offset tests in the D -
Diagnostic Step.
Only the equipped channels are visible. It is also possible to specify if a cycle should continue to run after
a failed flying zero offset test.
In the
Spindle Functional Test Limits
frame it is possible to set the limits used in the spindle functional
test. These limits are stored in the physical spindle. To make a change enter wanted values and press
Store to spindle
.
4.6.6.1 Static Zero Offset
To a large extent you can eliminate torque-measuring errors by performing zero offset check and
compensation. When such an operation is done is controlled by the execution of a D - Diagnostic Step.
Static zero offset
is measured without turning the spindle. The static zero offset is the average torque
measured during
Measuring time
. The absolute value of the static zero offset must be below
Maximum
Static Zero Offset
. If not, step status is set to
Fatal
and the error flag STZODIAG is set.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...