Tightening
9836 3521 01
333
6.5.4.10 Check torque rate
Parameters:
T Start
(Torque Start),
T Stop
(Torque Stop),
A Start
,
A Stop
,
TRL
(Torque rate low),
TRH
(Torque rate high)
,
Dev
(Deviation),
Falling Edge , Type
Function:
Measures and checks the Torque Rate (TR), that is, the ratio of torque vs. angle during a
single step or zone.
Measuring is started when the angle
Astart
has elapsed from that torque reached the value
Torque Start
. If
Falling Edge
is checked the measurement of
Astart
is started when the
torque falls below
Torque Start
. This is point (
A1
,
T1
).
Point (
A2
,
T2
) is the point where measuring is stopped, that is, when any of the following
conditions first is met:
- when the torque reaches the value
Torque Stop
- when the angle measured from
Torque Start
reaches
Astop
- when the torque reaches final torque, that is, the end of the step. This point is used only if
both
Torque Stop
and
Astop
are empty.
Torque Start
,
Torque Stop
,
Astart
, and
Astop
are all optional. If
Torque Start
is left
empty, then
Astart
is measured from the start of the step. Leaving
Astart
empty is equal to
setting
Astart
to zero. Leaving
Torque Stop
and/or
Astop
empty deactivates the
respective check as stop conditions.
Depending on the setting of
Type
, different methods are used to calculate the Torque Rate:
Type ‘Least Square’:
The check calculates a straight line with least square method using 15 points evenly spread
between the angles A1 and A2, the points A1 and A2 are always included. The minimum
distance between two points is 2 deg, so if the total angle between A1 and A2 is less than
28 degrees fewer points are used.
Type ‘Two point’:
The Torque Rate is calculated as: TR = (T2
– T1) / (A2 – A1)
The formula for the calculated line is:
T = TR * A + m, there T is the torque, A the angle and TR the calculated Torque Rate.
The calculated TR is checked to be within the limits TRH and TRL.
This function also checks that the torque does not deviate more than Dev from a straight
line between the points (A1, T1) and (A2, T2). The Deviation in sample k, DEV(k), is
calculated as:
DEV(k) = ABS[T(k)
– (A(k) * TR + m)]
The highest found deviation is reported in the result variable TorqueRate Dev.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...