PLC
224
9836 3521 01
Variable
Type
Use
GENOUT_1 ...
GENOUT_5
INT
General output. Can be used for selection of double encoders or
change of spindle direction. See chapter: Spindle Set Up.
FREESTRING
STRING(40)
The value of this output can be included in the cycle data result as
the station level result variable "Free Str". Sampled on the positive
edge of START.
FREESTRING2
STRING(40)
The value of this output can be included in the cycle data result as
the station level result variable "Free Str 2". Sampled on the positive
edge of START.
FREESTRING3
STRING(40)
The value of this output can be included in the cycle data result as
the station level result variable "Free Str 3". Sampled on the positive
edge of START.
FREENUM1
DINT
The value of this output can be included in the cycle data result as
the station level result variable "Free No 1". Sampled on the positive
edge of START.
FREENUM2
DINT
The value of this output can be included in the cycle data result as
the station level result variable "Free No 2". Sampled on the positive
edge of START.
DISABLE_TESTBOLT
BOOL
Set this output TRUE to disable the usage of the ToolsTalk
PowerMACS Test Bolt form for this station. See also chapter: Test
Bolts.
ACKACCESSEVENT
BOOL
Set this output True to mark all events of type "Access" as observed
(see View Event Log and PLC Event handling).
ACKPOWERUPEVENT
BOOL
Set this output True to mark all events of type "Power up" as
observed (see View Event Log and PLC Event handling).
ACKCHKEVENT
BOOL
Set this output True to mark all events of type "Check" as observed
ACKSWEVENT
BOOL
Set this output True to mark all events of type "Software" as
observed (see View Event Log).
ACKSYSERREVENT
BOOL
Set this output True to mark all events of type "System error" as
observed (see View Event Log).
ACKMODEVENT
BOOL
Set this output True to mark all events of type "Modification" as
observed (see View Event Log).
ACKHWEVENT
BOOL
Set this output True to mark all events of type "Hardware" as
observed (see View Event Log).
ACKEMERGEVENT
BOOL
Set this output True to mark all events of type "Emergency stop" as
observed (see View Event Log).
ACKGENERALEVENT
BOOL
Set this output True to mark all events of type "General" as
observed (see View Event Log).
ACKXCOMEVENT
BOOL
Set this output True to mark all events of type "External
communication" as observed (see View Event Log).
ACKSETUPEVENT
BOOL
Set this output True to mark all events of type "Set up" as observed
(see View Event Log).
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...