9836 3521 01
629
Code
Comp
Code
Type
Severity Event string
770
106
Check
Error
Step %d, Diagnostic: Calib. failed on T1. Meas. %f, expected %f
771
107
Setup
Error
Step %d, Diagnostic: Incorrect configuration
772
108
Setup
Error
Step %d, Check: Incorrect Peak torque
773
109
Setup
Error
Step %d, Check: Incorrect Torque in angle window
774
110
Check
Error
Step %d, Check: Torque in angle window failed
775
111
Setup
Error
Step %d, Check: Incorrect Torque in time window
776
112
Check
Error
Step %d, Check: Torque in time window failed
777
113
Setup
Error
Step %d, Check: Incorrect Mean torque
778
114
Check
Error
Step %d, Check: Mean torque failed
779
115
Setup
Error
Step %d, Check: Incorrect T/T3
780
116
Check
Error
Step %d, Check: T/T3 failed
781
117
Setup
Error
Step %d, Check: Incorrect Angle
782
118
Check
Error
Step %d, Check: Angle failed
783
119
Setup
Error
Step %d, Check: Incorrect Current
784
120
Setup
Error
Step %d, Check: Incorrect Clamp Load
785
121
Setup
Error
Step %d, Check: Incorrect Time
786
122
Setup
Error
Step %d, Check: Incorrect Post view
787
123
Check
Error
Step %d, Check: Post view Torque failed
788
504
Check
Error
Step %d, Check: Post view Torque failed (Buffer overflow)
793
128
General
Warning
Spindle %d: Time for service. %d cycles since service (%d to
many)
794
129
Setup
Error
Spindle: No program for mode %d
795
130
Setup
Error
Cycle data too big, step %d not stored
796
131
Check
Error
Step %d, Monitoring: Final torque could not be evaluated
797
132
Check
Error
Step %d, Monitoring: Threshold angle could not be evaluated
798
133
Check
Error
Step %d, Monitoring: Torque rate could not be evaluated
(interval %d)
799
134
Check
Error
Step %d, Monitoring: Yield point torque could not be evaluated
800
135
Check
Error
Step %d, Monitoring: Yield point angle could not be evaluated
801
136
Check
Error
Step %d, Check: Peak torque. %f < %f
802
137
Check
Error
Step %d, Check: Torque in angle window. %f < %f
803
138
Check
Error
Step %d, Check: Torque in time window. %f < %f
804
139
Check
Error
Step %d, Check: Mean torque. %f < %f
805
140
Check
Error
Step %d, Check: Angle. %f < %f
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...