Peripheral Devices
416
9836 3521 01
Example for an ID device:
For it you must specify Type, which is one of Barcode, Escort P&F and Escort AB.
Select a suitable port. There are several ports on a Tightening Controller that can be used for in and
output of data.
Port
Usage
Signal Interface
Serial 1
General serial communication
RS-232, RS-485
Serial 2
General serial communication
RS-232, RS-422, ST-Bus
CAN I/O port
I/O Device communication
CAN with DeviceNet
For the selected port you must also specify its characteristics: Baud Rate (300-115 200), Parity (None,
Even or Odd) and Data Bits (7 or 8). Number of Stop Bits is always 1.
Note!
Due to technical reasons you can only use two different baud rates on each TC.