Set Up and Maintenance
186
9836 3521 01
4.17.2
Test Bolts
The Test Bolt function gives you an alternative way to the execution of a tightening cycle, running all or
only one selected bolt for a station.
First chose which station to test using the
Station
combo box in the toolbar.
Depending on the status of the selected station the Test Bolt form may be disabled. The form is disabled
for this reason if:
The hardware Emergency input is inactive for the TC that executes the station (PLC station input
EMERGSTOPIN True).
The selected stations PLC output DISABLE_TESTBOLT is set True. See also the description of
the Station variables in the PLC section.
In either case an explanation of why the Test Bolt form is disabled is displayed at the top of the form.
With the
Bolt
combo box you may select a single bolt or
All Bolts
within the station. Note that if
All Bolts
is chosen and some bolts use the same spindle only the first occurring bolt for that spindle will be run and
an error message will be generated.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...