Basic Functions
9836 3521 01
67
If there is a subgroup, which has possible corrupt data, you can delete it. Click in the diagram on the
subgroup you want to delete. Press
Delete Subgroup
. This is possible only when the selection SPC and
TDA is active.
To the left current capability values are displayed. The window is automatically updated whenever a new
cycle is completed. Values displayed are calculated over same data as shown in the curve, for subgroups
or for short-term trend.
If Cp or Cpk is not presently within limits, a warning message is presented.
If you select
Histogram
you will be presented the following view:
This form displays the frequency distribution of the selected variable. The X-axis, displayed in the unit of
the variable, is divided in 20 classes scaled so that 25% of the screen is left of LTL, and 25% is right of
UTL.
The boundaries of each class are marked using dashed vertical lines where green indicates classes in
between LTL and UTL.
On Y-axis is shown the count of values with in each of the classes.
If you want to have the current view on paper, press
.
The viewed statistics is updated cyclically when online.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...