Basic Functions
102
9836 3521 01
Fixed Positions layout
Std. + TableSetting
Type of layout
to "Fixed Positions", the
Bolts to report
parameter to 5 (on the
Advanced CD settings form) and the following variable settings:
Station variables:
Variable
Width
Dec
Text
Station
8
yes
Time
24
yes
Status
9
yes
<New Line>
Bolt variables:
Variable
Width
Dec
Text
Bolt No
8
yes
<New Line>
Bolt T
7
1
yes
<New Line>
Bolt A
7
yes
<New Line>
Gives the following print out for a four-bolt station where only bolt 1, 2, and bolt 4 is executed when
printable format is selected:
Station: Stn 01 Time: 011030 09:40:58 Status: OK
Bolt No: 1
Bolt No: 2
Bolt No: 4
Bolt T: 15.1
Bolt T: 15.2
Bolt T: 15.4
Bolt A: 431
Bolt A: 432
Bolt A: 434