For one year from date of purchase, Malibu Lighting Corporation warrants the Malibu Power Pack against defects due to workmanship or materials to the original purchaser.
The Malibu Lighting Corporation’s obligations under this warranty are limited to the following guidelines:
•
This warranty does not cover units that have been altered/modified or damaged due to: normal wear, rust, abuse, improper maintenance and/or improper use.
•
This warranty does not cover surface scratches to fixtures or transformer, which is considered normal wear.
•
Malibu Lighting Corporation may elect to repair or replace damaged units covered by the terms of this warranty.
•
This warranty extends to the original purchaser only and is not transferable or assignable to subsequent purchasers.
Malibu Lighting Corporation requires reasonable proof of purchase. Therefore, we strongly recommend that you retain your sales receipt or invoice. To obtain repair or
replacement of your Malibu Power Pack under the terms of this warranty, please call Customer Service Department at 888-295-7348 for a Return Authorization Number and
further instructions. A receipt or proof of purchase will be required. Malibu Lighting Corporation will not be responsible for any units forwarded to us without a Return
Authorization Number.
EXCEPT AS ABOVE STATED, THE MALIBU LIGHTING CORPORATION MAKES NO OTHER EXPRESS WARRANTY.
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF PURCHASE. SOME
STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
ANY LIABILITY FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE FAILURE OF THE MALIBU POWER PACK TO COMPLY WITH THIS WARRANTY OR
ANY IMPLIED WARRANTY IS EXCLUDED. CUSTOMER ACKNOWLEDGES THAT THE PURCHASE PRICE CHARGED IS BASED UPON THE LIMITATIONS CONTAINED IN THE WARRANTY
SET OUT ABOVE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION
MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Durante un año a partir de la fecha de compra, Malibu Lighting Corporation garantiza al comprador original que las luces Malibu paquete de energía está libre de defectos
de materiales o mano de obra. Las obligaciones de Malibu Lighting Corporation con respecto a esta garantía se limitan a lo siguiente:
•
Esta garantía no cubre unidades que hayan sido alteradas/modificado o dañadas debido a: uso normal, herrumbre, maltrato, mantenimiento inadecuado y/o uso
inapropiado.
•
Esta garantía no cubre rayones superficiales a los accesorios o transformador, daño por herrumbre o por calor al acabado, lo cual se considera como uso normal.
•
Malibu Lighting Corporation puede decidir reparar o reemplazar las unidades dañadas cubiertas bajo los términos de esta garantía.
•
Esta garantía se otorga al comprador original únicamente y no es transferible o asignable a los compradores posteriores.
Malibu Lighting Corporation exige un comprobante de compra razonable. Por lo tanto, le recomendamos enfáticamente que retenga su recibo o factura de venta. Para
solicitar reparación o reemplazo de la Luces Malibu paquete de energía de conformidad con los términos de esta garantía, sírvase llamar al Departamento de Atención al
Cliente al 888-295-7348 para recibir un Número de autorización de devolución y otras instrucciones. Se requerirá el recibo o comprobante de compra. Malibu Lighting
Corporation no puede asumir responsabilidad por unidades que sean enviadas a nosotros sin un Número de autorización de devolución.
EXCEPTO POR LO INDICADO ARRIBA, MALIBU LIGHTING CORPORATION NO OTORGA NINGUNA OTRA GARANTÍA EXPRESA.
LAS GARANTÍAS IMPLÍCITAS DE COMERCIABILIDAD Y ADECUACIÓN CON UN FIN EN PARTICULAR SON DE DURACIÓN LIMITADA DE ACUERDO A LO INDICADO ARRIBA A
PARTIR DE LA FECHA DE COMPRA. ALGUNOS ESTADOS NO PERMITEN LIMITACIONES DE DURACIÓN DE UNA GARANTÍA IMPLÍCITA; POR LO TANTO, LA LIMITACIÓN ANTERIOR
PODRÍA NO SER APLICABLE EN SU CASO.
SE EXCLUYE CUALQUIER RESPONSABILIDAD POR DAÑOS INDIRECTOS, INCIDENTALES O CONSIGUIENTES DERIVADOS DE LA FALTA DE CUMPLIMIENTO DE ESTA GARANTÍA O
DE CUALQUIER GARANTÍA IMPLÍCITA DE LUCES MALIBU PAQUETE DE ENERGÍA. EL CLIENTE RECONOCE QUE EL PRECIO DE COMPRA COBRADO SE BASA EN LAS LIMITACIONES
CONTENIDAS EN LA GARANTÍA ANTERIOR. ALGUNOS ESTADOS NO PERMITEN LA EXCLUSIÓN O LIMITACIÓN DE LOS DAÑOS INCIDENTALES O CONSIGUIENTES; POR LO TANTO,
LA LIMITACIÓN O EXCLUSIÓN ANTERIOR PODRÍA NO SER APLICABLE EN SU CASO. ESTA GARANTÍA LE OTORGA DERECHOS LEGALES ESPECÍFICOS Y USTED PUEDE TENER
ADEMÁS OTROS DERECHOS QUE VARÍAN DE UN ESTADO A OTRO.
Malibu Lighting Corporation garantit Malibu bloc d'alimentation pendant 1 an à compter de la date d’achat contre les défauts de fabrication ou de matières à l’acheteur
initial. Aux termes de la présente garantie, les obligations de Malibu Lighting Corporation se limitent à ce qui suit:
•
La présente garantie ne couvre pas les fumoirs altérés, modifiés ou endommagés par suite : de l'usure normale, la corrosion, d'un usage abusif, d'un entretien inadéquat
ou d'une utilisation incorrecte.
•
La présente garantie ne couvre pas les rayures superficielles ou les dégâts/décoloration au fini occasionnés par la chaleur, car ils sont considérés comme faisant partie
de l’usure normale.
•
Malibu Lighting Corporation peut choisir de réparer ou remplacer les appareils endommagés couverts par les termes de la présente garantie.
•
La présente garantie ne s'adresse qu’à l’acheteur initial et ne peut être transférée ou cédée aux acheteurs ultérieurs.
Malibu Lighting Corporation exige une preuve d'achat raisonnable. Nous vous recommandons donc vivement de conserver votre preuve d'achat ou facture. Pour obtenir une
réparation ou le remplacement de votre Malibu bloc d'alimentation au titre de cette garantie, veuillez appeler le Service à la clientèle au 888-295-7348 pour obtenir un
numéro d'autorisation de retour et de plus amples instructions. Une réception ou une preuve d'achat est exigée. Le numéro d'autorisation de retour doit être clairement
indiqué sur la paroi extérieure de la boîte. Malibu Lighting Corporation n'est pas responsable de toutes unités retournés sans numéro d'autorisation de retour.
LA GARANTIE OFFERTE PAR MALIBU LIGHTING CORPORATION NE COUVRE EXPRESSÉMENT QUE CE QUI PRÉCÈDE.
LES GARANTIES TACITES DE VALEUR COMMERCIALE ET D’ADAPTATION À UN USAGE PARTICULIER SONT LIMITÉES À UN AN À COMPTER DE LA DATE DE L'ACHAT. CERTAINES
PROVINCES INTERDISENT DE LIMITER LA DURÉE D'UNE GARANTIE TACITE. LA LIMITE QUI PRÉCÈDE PEUT PAR CONSÉQUENT NE PAS S'APPLIQUER À L’ACHETEUR.
TOUTE RESPONSABILITÉ POUR DES DOMMAGES INDIRECTS, FORTUITS OU CONSÉQUENTS DUS À L’INOBSERVATION PAR L’ACHETEUR MALIBU BLOC D'ALIMENTATION DES
TERMES DE LA PRÉSENTE GARANTIE OU DE TOUTE GARANTIE TACITE EST EXCLUE. LE CONSOMMATEUR RECONNAÎT QUE LE PRIX D'ACHAT FACTURÉ EST BASÉ SUR LES DÉLAIS
DE PRESCRIPTION POUR LA GARANTIE DE L'ENSEMBLE CI-DESSUS. CERTAINS ÉTATS, PROVINCES OU PAYS NE PERMETTENT PAS L'EXCLUSION OU LA RESTRICTION DES
DOMMAGES INDIRECTS OU MATÉRIELS. PAR CONSÉQUENT, LES RESTRICTIONS OU LES EXCLUSIONS MENTIONNÉES CI-DESSUS POURRAIENT NE PAS S'APPLIQUER À VOTRE
CAS. CETTE GARANTIE VOUS DONNE DES DROITS SPÉCIFIQUES, ET VOUS POUVEZ ÉGALEMENT AVOIR D'AUTRES DROITS QUI VARIENT D'UNE PROVINCE À L'AUTRE.
GARANTIE LIMITÉE DE 1 AN
1 AÑO DE GARANTÍA LIMITADA
1 YEAR LIMITED WARRANTY
©2009 Malibu Lighting Corporation
Dallas, Texas 75244 U.S.A.
www.malibulights.com
158-00893
1100-9300-40
0609
A
B
C
D
5/8 inch
3 inch
1.6 cm
7.6 cm
Terminal Blocks
A B C
10 ft
(3m)
12 in (30 cm)
GFCI
TECHNICAL SPECIFICATIONS: 12 V ~ 300W
For dependable performance, use genuine Malibu replacement parts.
ML300RTWM/8100-9300-01 Model 300 Watt POWER PACK
READ INSTRUCTIONS BEFORE USING THIS PRODUCT
SAVE THESE INSTRUCTIONS
WARNING
WARNING
Suggestions to Solve Problems Quickly
1. Prepare Cable
2. Connect Cable to Power Pack
3. Place Fixtures and Route Cable
FCC
8. Set Time of Day
7. Set Timer ON / OFF Times
6. Hide Cable
5. Mount Power Pack
4. Attach Fixtures
Risk of Fire or Electrical Shock
Risk of Fire or Electrical Shock
Risk of Fire
Risk of Fire
Risk of Fire
This device complies with Part 18 of the FCC Rules.
Do not coil cable around power pack.
Total bulb wattages must not exceed a maximum of 300 watts.
•
Power pack SUITABLE FOR USE with submersible luminaires and pumps.
•
Install OUTDOORS ONLY. Use ONLY with 12 volt low voltage outdoor landscape lighting products.
•
Add up all bulb wattages for a maximum total of 300 watts.
•
Mount power pack at least 10 feet (3 m) from pool or spa.
•
Mount power pack vertically at least 12 inches (30 cm) above ground. Do not lay on the ground.
•
Plug power pack directly into an outdoor GFCI outlet with a weatherproof cover marked “wet location.”
•
Do not use extension cords.
•
Do not use in dwelling units.
•
When connecting wire at terminals, do not allow insulation to get under the clamping plate, and
firmly tighten the terminal screws.
•
Do not mix solid or stranded type wires under one screw.
•
Do not use cable smaller than 12 gauge.
•
Keep a minimum of 10 feet (3 m) of wire between the power pack and the first fixture.
•
Do not coil extra cable around the power pack. Leave extra cable at the end away from the power pack.
•
Do not repair or tamper with cord or plug.
•
Do not submerge power pack.
•
Do not connect two or more power packs in parallel.
•
Do not use with a dimmer.
•
If house circuit breaker trips when power pack is turned on, unplug power pack from AC outlet,
correct fault, and restore power. Plug power pack back into AC outlet.
•
Power pack and fixtures must be installed in compliance with national and all local electrical
codes and ordinances.
•
If necessary to splice cable, carefully follow instructions that came with the connector you have
purchased.
•
Use only with maximum 300 W (per circuit) lamp load.
LED fixtures
•
Do not use with fixtures that carry a Class 2 rating.
•
Do not modify fixtures.
•
Must follow all of manufacturers individual instructions.
Malibu cable is prepared and ready to connect to the power
pack. If using other cable, split one end of cable for about
3 inches (7.6 cm) being careful when splitting NOT to expose
the copper wire. Then strip 5/8 inch (1.6 cm) of insulation from
the end. Also, refer to strip length guide on the power pack.
Lay power pack on a flat, stable surface and insert the stripped
end of one wire under terminal clamping plate A. Then tighten
the screw. Repeat this procedure for clamping plate B. NOTE:
The C terminal is only used to connect an optional photo control.
Make sure there is no wire insulation under the clamping plate,
and firmly tighten the terminal screws.
Lay the fixtures out where you want to locate them. Be sure
they do not exceed the 300 watt rating of the power pack.
Route the low voltage cable to fixtures. If there is extra cable,
coil after the last fixture.
Be sure to leave a minimum of 10 feet (3 m) of wire between
the power pack and first fixture.
Order missing, damaged, or defective parts for new purchases only at:
www.malibulights.com
For customer service or to purchase
replacement parts please call Monday - Friday,
8:30 a.m. - 5:00 p.m. (CST)
888-295-7348
IMPORTANT: Please have product model number available when ordering.
YOU MUST KEEP YOUR RECEIPT FOR PROOF OF PURCHASE
Use only CSA or UL approved
low-voltage cable.
Use chart at right to
determine the minimum gauge cable to be
used, depending on the wattage of the
power pack. Using larger cable will increase
light output. For Malibu cable, contact your
supplier.
Do not use cable smaller than listed
in the table.
Turn power pack on. Attach fixtures to cable using cable
connectors as shown. Place one connector on each side of
the cable, then press together to lock. Prongs will pierce the
cable to make contact and fixture should light up. Continue
until all fixtures are connected. Leave about 12 in (30 cm) of
cable after the last fixture.
NOTE:
When power pack is on, you may hear a hum
This sound is considered normal, and does not affect the
performance of the unit.
To mount directly to a wall surface use screws as
shown, a minimum 12 inches (30 cm) off the ground.
Hang Power Pack onto screws.
Once all fixtures are in place and you are satisfied with their
locations, cable may be covered with mulch or buried up to
6 in (15 cm) deep.
Set ON and OFF times by setting tripper locations:
a.
Insert a red ON tripper
(A)
at the time you
want the lights to turn on.
b.
Insert a black OFF tripper
(B)
at the time
you
want the lights to turn off.
c.
Use a second set of red and black trippers
if you want another ON/OFF cycle.
Set time of day on the timer as follows:
a.
Make sure the Power Pack is plugged in
and turned ON.
b.
Turn the dial clockwise to the present
time of day as shown by the arrow
(C).
c.
Turn the dial one or more complete
revolutions then return to the present
time of day.
The lights will now turn ON and OFF at the times you have set.
You can manually operate the lights by turning the Manual ON/
OFF Switch counter clockwise
(D).
•
Make sure power pack is plugged in. Is outlet working?
•
Turn manual ON/OFF switch to “ON” or rotate dial so “ON” tripper
passes time line indicator.
•
Is lamp burned out? Use another lamp to test.
NOTE: This lighting system is designed to last many years under
normal conditions. However, lamps eventually burn out and operating
with one lamp out can shorten the life of the others. Conditions beyond
control (high input voltage, poor voltage regulation, etc.,) will also
affect lamp life. IT IS IMPORTANT TO REPLACE BURNED OUT LAMPS
PROMPTLY.
WARNING
Power Pack
Wattage
Minimum
Gauge Cable
217-300
12
157-216
14-12
121-156
16-14-12
0-120
18-16-14-12
WARNING
WARNING
WARNING
weatherproof
cover not included.
http://waterheatertimer.org/Malibu-power-pack-stopped-working.html
____________________________________________________________________
http://waterheatertimer.org/Malibu-power-pack-stopped-working.html